How to check if the cooling water circulation of the air separation equipment is fully connected?

How to check if the cooling water circulation of the air separation equipment is fully connected?
Apr 17, 2025
Author: DEAR AST

Checking whether the cooling water circulation of the air separation equipment is fully connected is an important step to ensure the normal operation of the equipment.
Observe the operation status of the cooling water system, check that the water level in the water tank is normal, and there are no leaks or abnormal drops. Observe the flow of water and observe the flow of cooling water through transparent pipes or observation windows. Check the connection of the pipeline, inspect all interfaces of the cooling water pipeline one by one, and ensure that there are no leaks or looseness at the interfaces; Check that the installation bracket of the pipeline support is stable and not loose. Check the valve status and ensure that all valves in the cooling water system (such as globe valves, regulating valves, check valves, etc.) are in the correct working condition. Detect the flow rate and pressure of cooling water, install flow meters and pressure gauges, and compare the design parameters. Check the water quality of the cooling water and regularly test the water quality: Take samples regularly to test the water quality of the cooling water, including indicators such as pH value, turbidity, hardness, chloride ion content, etc. Clean and replace the cooling water, promptly clean the cooling system and replace it with new cooling water based on the water quality test results. Replacing with new cooling water can prevent water quality deterioration from causing damage to the system.
Comprehensive inspection and debugging, comprehensive inspection, on the basis of completing the above inspections, conduct a comprehensive inspection of the cooling water system. Ensure that the cooling water system can operate normally.

DEAR Air Separation Solve YourHow to check if the cooling water circulation of the air separation equipment is fully connected?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top