当前位置: Home / Faq / Small air separation FAQ /

What requirements should be met when assembling gauge tubes and cold boxes for small air separation unit?

What requirements should be met when assembling gauge tubes and cold boxes for small air separation unit?
Apr 16, 2025
Author: DEAR AST

Small air separation unit assembly gauge tube should meet the following requirements: gauge tube should be degreased, and it is appropriate not to test pressure after assembly; gas gauge tube (such as pressure gauge tube) should not be in contact with cold equipment or cold tube, the distance should not be less than 2000 mm; liquid level gauge tube of the upper valve tube should be made from the container for 1/10. slope upward sloping to the valve, the lower valve tube from the container in the horizontal lead, in close to the wall of the cold box about 300 The lower valve pipe is led from the container horizontally and is bent into an omega shape to the valve within about 300 mm of the wall of the cooler (hot zone part).

 

The small air separation unit should meet the following requirements: the welding seam on the outer surface should be continuously welded and should not leak; the non-lead dip should not exceed 2/1000; the flange of the vertical liquefied gas pump should not exceed 1/1000 in its plane.

 

Dear Air Separation continues to develop new technologies for small air separation unit and large air separation unit, and applies strict requirements in all aspects of assembly units to ensure high quality units.

5200Nm3h型成套设备

DEAR Air Separation Solve YourWhat requirements should be met when assembling gauge tubes and cold boxes for small air separation unit?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Membrane separation is a technology that uses separation membranes as the core for the selective separation, concentration and purification of substances. The basic principle is to use the different rates of dissolution and diffusion of each gas component in the separation membrane at a certain pressure, and therefore the different rates of permeation through the fibre membrane walls due to the partial pressure d...
2025.06.06
The liquid oxygen pump is a kind of low temperature liquid pump. It is used as the liquid oxygen circulating pump in the main condensing evaporator in the internal compressed air separation process to increase the pressure of liquid oxygen and output liquid oxygen.
2025.06.05
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top