When the full low pressure oxygen generator begins to accumulate liquid oxygen, is it necessary to keep the liquid level? Why?

When the full low pressure oxygen generator begins to accumulate liquid oxygen, is it necessary to keep the liquid level? Why?
Apr 15, 2025
Author: DEAR AST
Question Reply

The start-up phase of the whole low-pressure oxygen generator is that liquid empty appears first in the lower tower, and then liquid oxygen appears in the upper tower. The cooling amount needed to accumulate liquid in the tower mainly comes fromExpander, Make use of the low temperature gas after expansion to make part of the air liquefaction in the liquid purifier. But the upper tower itself can not produce liquid, it mainly depends on the liquid from the lower tower into the upper tower. In the phase of hydrops, in order to accumulate the liquid level as soon as possible, the cooling volume should be transferred to the tower as much as possible, the phenomena of overcooling, temperature difference at the hot end and cold loss increase caused by excess cooling of switching heat exchanger should be avoided.


As for how to recycle and transfer the cold volume of the air expansion into the tower, whether it is by the liquid purifier to transfer the cold volume to the lower tower first, and then to the upper tower, it is OK to transfer directly to the upper tower through the supercooler. If the cold fluid channel of the liquid air cooler can be directly connected with the channel behind the expansion machine (for example, set the cooler and the liquid purifier together), in other words, the liquid-air supercooler can be used to recover part of the cooling capacity of the expansion gas and directly give it to the upper tower, and the supercooler can act as a liquid purifier at the same time. That is to transfer the cooling volume to the tower by the liquid purifier and supercooler at the same time, which can accelerate the accumulation of liquid. In this case, the liquid level of the lower tower can be temporarily ignored and kept, and the air throttle valve can be opened to make as much gas included in the liquid air as possible pass through the supercooler to strengthen the heat exchange of the supercooler, to recycle more cold energy. Some oxygen generator does not even set a liquid purifier in the process design, but only uses it as a liquid purifier when the supercooler is started, and begins to accumulate liquid from the top tower.

DEAR Air Separation Solve YourWhen the full low pressure oxygen generator begins to accumulate liquid oxygen, is it necessary to keep the liquid level? Why?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top