When the full low pressure oxygen generator begins to accumulate liquid oxygen, is it necessary to keep the liquid level? Why?

When the full low pressure oxygen generator begins to accumulate liquid oxygen, is it necessary to keep the liquid level? Why?
Apr 15, 2025
Author: DEAR AST
Question Reply

The start-up phase of the whole low-pressure oxygen generator is that liquid empty appears first in the lower tower, and then liquid oxygen appears in the upper tower. The cooling amount needed to accumulate liquid in the tower mainly comes fromExpander, Make use of the low temperature gas after expansion to make part of the air liquefaction in the liquid purifier. But the upper tower itself can not produce liquid, it mainly depends on the liquid from the lower tower into the upper tower. In the phase of hydrops, in order to accumulate the liquid level as soon as possible, the cooling volume should be transferred to the tower as much as possible, the phenomena of overcooling, temperature difference at the hot end and cold loss increase caused by excess cooling of switching heat exchanger should be avoided.


As for how to recycle and transfer the cold volume of the air expansion into the tower, whether it is by the liquid purifier to transfer the cold volume to the lower tower first, and then to the upper tower, it is OK to transfer directly to the upper tower through the supercooler. If the cold fluid channel of the liquid air cooler can be directly connected with the channel behind the expansion machine (for example, set the cooler and the liquid purifier together), in other words, the liquid-air supercooler can be used to recover part of the cooling capacity of the expansion gas and directly give it to the upper tower, and the supercooler can act as a liquid purifier at the same time. That is to transfer the cooling volume to the tower by the liquid purifier and supercooler at the same time, which can accelerate the accumulation of liquid. In this case, the liquid level of the lower tower can be temporarily ignored and kept, and the air throttle valve can be opened to make as much gas included in the liquid air as possible pass through the supercooler to strengthen the heat exchange of the supercooler, to recycle more cold energy. Some oxygen generator does not even set a liquid purifier in the process design, but only uses it as a liquid purifier when the supercooler is started, and begins to accumulate liquid from the top tower.

DEAR Air Separation Solve YourWhen the full low pressure oxygen generator begins to accumulate liquid oxygen, is it necessary to keep the liquid level? Why?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top