How to operate and manage the rectification tower of air separation equipment

How to operate and manage the rectification tower of air separation equipment
Aug 25, 2022
Author: DEAR AST

Differential pressure gauges are set on the upper column, lower column, crude argon column and pure argon column of the air separation unit to measure the resistance of each column in the rectification process. The resistance value measured after the unit is started for the first time and adjusted to normal shall be used as the operation basis of the unit. When the resistance decreases, it indicates that there is liquid leakage, or the liquid level on the tray is too low, or the processing gas volume is insufficient (decreased). At this time, the reason must be found out. When the resistance increases, it is usually caused by the blockage of the tray. This situation can be eliminated only by heating the rectification column; If it is caused by load, the air intake and oxygen production shall be analyzed and adjusted according to the actual situation.

When the liquid level at the bottom of the rectification column rises too high, resulting in the submergence of the bottom tray, the column will be flooded. At this time, the resistance in the column will increase significantly, and it should be adjusted again after the liquid is discharged.

DEAR air separation has rich experience in project management, engineering design, procurement and infrastructure supporting services in the air separation industry, and is committed to providing customers with complete and efficient infrastructure supporting solutions to meet their needs. In the process of equipment manufacturing and installation, there are detailed management and operation requirements for each subdivisional equipment to ensure the high-quality operation of the equipment.

DEAR Air Separation Solve YourHow to operate and manage the rectification tower of air separation equipmentYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
 The purpose of the blowing is to clean out the residual slag, aluminium chips and other debris from the piping and vessels. the air source for blowing is provided by the turbine compressor, and the air cooling tower must be activated. 3. blowing principle, first outside the tower, after the tower, blowing brush to be one after another, in the blowing with the air pressure: low pressure system. Should be maintained at 40 a 50kpa high pressure system: should be maintained at 250 ~ 400k...
2025.07.23
Due to improper adjustment of seal gas pressure during operation, liquid oxygen pump can not pump liquid or leak.   From the quality point of view, when the sealing pressure is too high, there will be gas leakage into the pump through the labyrinth seal, resulting in the impeller with gas or even idling, resulting in liquid injection or pressure drop; when the air pressure before sealing is too low, there will be liquid oxygen leakage.   From the quantity point of view, when (p1-p3...
2025.07.22
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top