Blowing and brushing is to remove the remaining water, impurities and dust in the pipe. The normal temperature dry air from the molecular sieve purification system is used for blowing and brushing. In the process of blowing, the amount of each blowing air shall be checked and adjusted frequently to ensure that all pipelines should be blown. It can be divided into regions and segments, and carried out step by step according to the pressure, and from the inside to the outside according to the process flow.

Precautions: when purging the air pressure, the high-pressure system should be kept at 3.0 ~ 3.5Mpa, the medium pressure system should be kept at 0.25 ~ 0.4MPa, and the low-pressure system should be kept at 0.04 ~ 0.05Mpa. Overpressure purging is not allowed. When the pressure is insufficient, equipment and pipeline should be purged one by one after boosting. In order to prevent impurities in the pipeline outside the tower from being brought into the fractionator, the air outside the tower, waste nitrogen pipeline and pressurized gas pipeline should be purged first, and then the equipment pipeline inside the tower should be purged after being purged and connected with the cold box pipeline. The inlet and outlet ends of the booster turbine expander and the inlet and outlet ends of the process liquid argon pump, the medium pressure liquid argon pump and the medium pressure liquid oxygen pump shall be disconnected and blocked with blind plates during the blowing stage, and shall not be removed until the blowing is completed. During purging, remove all flow orifice plates for metering, and install all orifice plates after purging. For the pressurized end of the pressurized air, a pipeline shall be temporarily connected to the site to boost the pressure, and the pipeline shall be removed after purging. At the same time, pay attention to whether each valve can be opened flexibly and smoothly during purging, and deal with problems in time if found. At the later stage of purging, remove all gauge pipe valves and safety valves for purging. After purging, put all valves in the fully closed state.

DEAR air separation has deeply studied the relevant auxiliary technologies of various equipment, has long experience in production and manufacturing, and the technology is mature and standardized.

DEAR Air Separation Solve YourWhat matters should be paid attention to in the blowing out of air separation equipment pipesYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant piston compressor clearance volume is: the compressor at the end of the exhaust, the piston and the cylinder end of the wall between the residual part of the high pressure gas occupied by the cylinder volume. The existence of the residual volume directly reduces the exhaust volume of the compressor, at the same time, the suction of this part of the high pressure gas expansion, will also cause a delay in the suction process, the reduction in suction volume, ultimately ...
2026.02.11
All low pressure air separation units are usually equipped with nitrogen water precoolers. It mainly uses the unsaturation of nitrogen in sewage to evaporate part of water. As the water evaporates, it absorbs the latent heat of vaporization to lower the temperature of the cooling water, which is then used to cool the treated air and lower the temperature of the air entering the column. Therefore, it includes air cooling column and water cooling column. The basic purpose of setting up nitrogen precooler is to reduce the air temperature entering the air separation column and avoid the temperature fluctuation greatly. Because the inlet air temperature directly affects the operation conditions of the switching heat ex-changer and distillation column, as well as the economy of the whole air separation unit. In the design, the air temperature entering the column is usually set at 30 ° C. When the inlet temperature of the column is higher than the design index during operation, the throttl
2026.02.10
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top