Low temperature valve stuck at low temperature

Low temperature valve stuck at low temperature
Aug 04, 2022
Author: DEAR AST

When the low-temperature valve rotates flexibly at room temperature, and it is not flexible or even cannot be opened at low temperature, this situation is generally caused by the following reasons: the material of the valve rod and the valve rod nut is different. Generally, the valve rod is stainless steel, and the valve rod nut is brass. Because the linear expansion coefficient of the two materials is different, the shrinkage of brass is larger than that of stainless steel at low temperature, causing the screw thread to bite; If the heating at the valve is not complete, or the valve packing flows in and out, freezing will also make it difficult to open the valve; In addition, improper fixing of the valve during installation, unreasonable configuration of the valve and pipeline, and change of valve position at low temperature may cause the valve to jam.

The third stage of the intelligent control system developed by DEAR will expand the application of related industries on the basis of full cultivation of the air separation industry. Extend the mature [intelligent numerical control system] to related industries. For example, it is widely involved in industries with alternating gas and liquid phases: the development and transportation of hydrogen energy, synthetic ammonia and related processes, methanol, biomass energy, carbon dioxide recovery of coke oven gas, biogas purification, natural gas and other industries. It will help the intelligent management and energy consumption reduction of the industries involved.

DEAR Air Separation Solve YourLow temperature valve stuck at low temperatureYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top