The air separation unit needs to be adjusted during normal operation and production.

Rectification control: the liquid and air level of the lower tower must be stable and can be automatically controlled by the valve to maintain the liquid and air level at the specified height. The control of rectification process is mainly realized by the opening of the valve. When the opening is increased, the oxygen content in liquid nitrogen increases. On the contrary, when the opening of the valve is reduced, the oxygen content in liquid nitrogen decreases. The purity of product gas will also be affected by the amount of product gas taken out. If the amount of product gas taken out is increased, its purity will decrease. On the contrary, if the amount of product gas taken out is reduced, its purity will increase. Adjust the argon fraction by adjusting the amount of oxygen and nitrogen out of the tower, turn on the oxygen extraction amount and turn down the nitrogen extraction amount, then the argon content in the fraction will increase, and the nitrogen content may also increase; On the contrary, if the nitrogen extraction volume is turned on and the oxygen extraction volume is turned off, the argon content in argon will decrease, and the nitrogen content will also decrease. In addition to adjusting the composition of argon fraction, the adjustment of crude argon can also adjust the liquid level of the crude argon condenser. With the increase of liquid level, the resistance of crude argon tower increases, the oxygen content in crude argon decreases, and the nitrogen content in crude argon decreases. The purity adjustment of pure argon can be achieved by increasing the heat load of evaporator and condenser, increasing the exhaust gas extraction from the tower top, and reducing the reflux of refined argon tower.

DEAR company has technical advantages, and engineering and technical personnel with actual equipment operation experience carry out operation management for customers to ensure the long-term, stable and safe operation of user equipment.

DEAR Air Separation Solve YourHow to control rectification in normal operation of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant piston compressor clearance volume is: the compressor at the end of the exhaust, the piston and the cylinder end of the wall between the residual part of the high pressure gas occupied by the cylinder volume. The existence of the residual volume directly reduces the exhaust volume of the compressor, at the same time, the suction of this part of the high pressure gas expansion, will also cause a delay in the suction process, the reduction in suction volume, ultimately ...
2026.02.11
All low pressure air separation units are usually equipped with nitrogen water precoolers. It mainly uses the unsaturation of nitrogen in sewage to evaporate part of water. As the water evaporates, it absorbs the latent heat of vaporization to lower the temperature of the cooling water, which is then used to cool the treated air and lower the temperature of the air entering the column. Therefore, it includes air cooling column and water cooling column. The basic purpose of setting up nitrogen precooler is to reduce the air temperature entering the air separation column and avoid the temperature fluctuation greatly. Because the inlet air temperature directly affects the operation conditions of the switching heat ex-changer and distillation column, as well as the economy of the whole air separation unit. In the design, the air temperature entering the column is usually set at 30 ° C. When the inlet temperature of the column is higher than the design index during operation, the throttl
2026.02.10
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top