当前位置: Home / Faq / High purity nitrogen air separation FAQ /

What are the development history, current situation and main technical problems of the purification system of air separation equipment

What are the development history, current situation and main technical problems of the purification system of air separation equipment
Sep 06, 2024
Author: DEAR AST

The molecular sieve adsorber of the purification system of the air separation unit is used to remove water, carbon dioxide and some hydrocarbons from the feed air, so as to ensure that the subsequent fractionator system will not freeze.

In the development process, the early air separation unit placed the removal of water, carbon dioxide and hydrocarbons in a low-temperature environment, which was synchronized with heat exchange. It has gone through the stages of cold accumulator and switching plate process. The shortcomings of the above two stages are relatively prominent. Especially in operation, operation cycle, extraction rate and energy consumption. Development status, use molecular sieve adsorbent to remove the above impurities. The adsorber adopts vertical or horizontal structure according to the size of the device. It is decided to use single or double layers according to the working environment. According to practical experience, most large-scale units adopt horizontal double bed structure.

The air separation industry is tackling major technical problems in the purification system

a. Effective solution to the problem of uniform distribution of air flow;

b. Effective solution to the problem of thermal expansion and cold contraction deformation of large cross-section bed under alternating temperature;

c. Elimination of wall flow effect;

d. Ensure the flatness of the bed surface;

e. Treatment of powder falling from molecular sieve adsorber.

With the increasing size of the unit, Deere air separation is leading the industry in tackling key technical problems, discussing with each other among industries, and ensuring the high quality and efficiency of manufacturing equipment.

DEAR Air Separation Solve YourWhat are the development history, current situation and main technical problems of the purification system of air separation equipmentYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:   First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;   Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be man...
2024.11.21
How is the ratio of individual gases adjusted in an air separation plant?
2024.11.20
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top