当前位置: Home / Faq / Liquefied air separation FAQ /

The liquid air separation plant industrial design status

The liquid air separation plant industrial design status
May 27, 2022
Author: DEAR AST

In recent years, with the growth of the production and sales of liquid air separation plants, the market share has been increasing, but on the other hand, the overall technology of the equipment is poor, there are problems such as unattractive appearance, unclear and unclear logo, and unfriendly human-machine control interface. In order to further stabilise and develop the market and improve the recognition of the overall image of the liquid air separation plants, the industrial design of small air separation units, large air separation units and liquid air separation plants is imminent. In this paper, on the basis of the product design, the design concept and ideas are changed, mainly focusing on the design of the whole machine appearance of small air separation units, large air separation units and liquid air separation plants, the design of a full set of process lines, the design of a full set of warnings and explicit signs, the design of the human-machine interface and the application of industrialised design. In order to further improve the simplicity and convenience of user operation and the aesthetics of the small air separation units, large air separation units and liquid air separation plants, we design products with stable and reliable performance, outstanding industrial design, in line with market demand, to meet the current market requirements for clear and refined equipment, improve the overall process and appearance of the small air separation units, large air separation units and liquid air separation plants, improve the overall quality of the small air separation units, large air separation units and liquid air separation plants, facilitate user operation and improve small air separation units, large air separation units and liquid air separation plants recognition.
DEAR Design and Research Institute has a professional R&D team of over 30 people, led by more than 20 senior engineers with many years of R&D and design experience, and a group of competent and dynamic innovative talents specialising in small air separation units, large air separation units and liquid air separation plants and control engineering, deep cooling and kinetic engineering.

21
Translated with www.DeepL.com/Translator (free version)

DEAR Air Separation Solve YourThe liquid air separation plant industrial design statusYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top