Why can the lower tower of the distillation column of a small air separation unit not pump dirty liquid nitrogen?

Why can the lower tower of the distillation column of a small air separation unit not pump dirty liquid nitrogen?
Feb 27, 2025
Author: DEAR AST

Oxygen generators are switchable heat exchanger process oxygen generators and molecular sieve pressurised expansion process oxygen generators.

 

The pure liquid nitrogen supplied to the upper tower is less and a stream of dirty liquid nitrogen can be pumped to the upper tower.

 

The oxygen generator of the pressurised expansion process, because there is no restriction of self-scavenging, so the amount of pure gas nitrogen product is increased substantially, except to ensure that the molecular sieve purifier is regenerated with dirty gas nitrogen, all other nitrogen products can be sent out as pure gas nitrogen products, with a ratio of pure nitrogen production to oxygen production of 3 - 3.5 times. In this way, the lower tower requires a large reflux ratio to ensure the amount and purity of pure nitrogen, which is then fed into the upper tower as a reflux.

 

In addition, due to the use of pressurised expansion, the unit cooling capacity of the expansion mass is higher, and the expansion volume required to supplement the same cold loss is smaller and generally does not exceed the amount of air allowed into the upper tower, therefore, there is no need to pump dirty liquid nitrogen to directly increase the reflux ratio of the distillation section.

 

Dear Air Separation has experience in manufacturing, pure gas nitrogen products with a large output of oxygen generators in the lower tower generally do not pump dirty liquid nitrogen. As a result in small air separation unit we do not pump dirty liquid nitrogen, the lower tower has fewer pumping ports, piping and valves, and the process is simplified.

20

DEAR Air Separation Solve YourWhy can the lower tower of the distillation column of a small air separation unit not pump dirty liquid nitrogen?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Small air separation unit is the unit that separates air into oxygen and other gases by first compressing and cooling the air into a liquid state and then using the characteristic that oxygen has a different boiling point to other gases in the air to obtain oxygen and liquid oxygen by evaporation and separation, as well as other rare gases as required.Liquid oxygen is produced using the cryogenic separation of air. The basic principle is to u...
2025.04.02
The pressure relief of molecular sieve in the purification system is generally rapid in the early stage, not complete and running overtime in the later stage. The pressure relief degree is adjusted by the manual stop valve in front of the pressure relief valve. Through practical adjustment, no matter how it is adjusted, the pressure relief in front is fast, or the pressure can not be exhausted. It is suggested that the valve positioner should be added to the automatic pressure relief valve, and the pressure linear adjustment should be programmed, so that the impact on molecular sieve will be much smaller.
2025.04.01
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top