Influence on purity of liquid nitrogen removal amount in lower column of air separation unit

Influence on purity of liquid nitrogen removal amount in lower column of air separation unit
Jan 23, 2026
Author: DEAR AST
Question Reply

The amount of liquid nitrogen removed from the lower column of the air separation unit will affect the purity of the liquid nitrogen in the lower column and the oxygen enriched liquid air at the bottom of the column. When the liquid nitrogen removal amount of the lower column increases, the reflux liquid participating in the heat and mass exchange of the lower column will be reduced, the temperature rise of the rising steam on the column plate will be correspondingly reduced, the condensation of the rising steam will not be sufficient, the oxygen component will be condensed less, the purity of nitrogen at the column top will be reduced, and the purity of liquid nitrogen will be naturally reduced. At the same time, the temperature rise of the downflow liquid will increase, the liquid evaporation will be more sufficient, more nitrogen components will be evaporated to the top of the column, and the purity of the liquid air at the bottom of the column will be improved accordingly.

DEAR Air Separation Solve YourInfluence on purity of liquid nitrogen removal amount in lower column of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
What is the oxygen extraction rate?
2026.08.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top