Influence on purity of liquid nitrogen removal amount in lower column of air separation unit

Influence on purity of liquid nitrogen removal amount in lower column of air separation unit
Jan 23, 2026
Author: DEAR AST
Question Reply

The amount of liquid nitrogen removed from the lower column of the air separation unit will affect the purity of the liquid nitrogen in the lower column and the oxygen enriched liquid air at the bottom of the column. When the liquid nitrogen removal amount of the lower column increases, the reflux liquid participating in the heat and mass exchange of the lower column will be reduced, the temperature rise of the rising steam on the column plate will be correspondingly reduced, the condensation of the rising steam will not be sufficient, the oxygen component will be condensed less, the purity of nitrogen at the column top will be reduced, and the purity of liquid nitrogen will be naturally reduced. At the same time, the temperature rise of the downflow liquid will increase, the liquid evaporation will be more sufficient, more nitrogen components will be evaporated to the top of the column, and the purity of the liquid air at the bottom of the column will be improved accordingly.

DEAR Air Separation Solve YourInfluence on purity of liquid nitrogen removal amount in lower column of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top