Adjustment of seal gas pressure and flow in liquid nitrogen pump

Adjustment of seal gas pressure and flow in liquid nitrogen pump
Jul 18, 2023
Author: DEAR AST
Question Reply

In the internal compression process air separation plant, we generally select the the multistage centrifugal pump as the liquid nitrogen pump. In order to ensure the stable operation of the liquid nitrogen pump, the pump seal mostly adopts the structure of gas-filled labyrinth seal.

 

The seal gas needs enough flow to warm the cryogenic liquid leaking from labyrinth seal. When the seal gas flow decreases to a critical point, the exhaust temperature of the seal gas will drop greatly and cause the interlock shutdown of the pump. With the pump running in the unstable state for a long time, the labyrinth seal will be worn and the gap will be increased, resulting in the increase of seal gas consumption, seal mixture outlet with liquid phenomenon, and causes the exhaust temperature of seal gas to decrease. In addition, the blockage of inlet pipeline filter by mechanical impurities and impurities in the filter screen of self regulating valve will also cause the seal gas flow to be too low.

 

The use principle of seal gas is not only to prevent liquid leakage along the outside of the pump, but also not to allow too much seal gas into the pump, resulting in the liquid nitrogen pump with gas phenomenon. It is suggested that the seal gas pressure can be adjusted by adding self regulating valve. When adjusting the seal gas pressure, it is necessary to ensure that the seal gas inlet pressure is higher than the labyrinth inlet pressure, which is 0.1-0.4Mpa, and the labyrinth inlet pressure is greater than the mixed gas pressure at the labyrinth outlet, which is  0.1-0.2Mpa. In order to prevent the equipment from being damaged by low temperature, it is necessary to ensure that there is no leakage of cryogenic liquid at the labyrinth seal. It is suggested to set a temperature sensor on the side near the pump body in the coupling guard to measure whether there is leakage at the sealing point, so as to give an alarm in time.

DEAR Air Separation Solve YourAdjustment of seal gas pressure and flow in liquid nitrogen pumpYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
What is the oxygen extraction rate?
2026.08.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top