Home / All Air Separation tags /

Emergency shutdown of air separation unit

Emergency shutdown of air separation unit
After the emergency shutdown of the air separation unit, the key points, sequence and measures of each system shall be made according to the logic and usage of the unit.
News of Emergency shutdown of air separation unit
More
Aug 26, 2020
On August 24, it was reported that Kaifeng DEAR air separation Industrial Co., Ltd. (hereinafter referred to as DEAR air separation) and Hanyuan Bilif
Aug 19, 2020
It was reported on August 17 that Kaifeng DEAR air separation Industrial Co., Ltd. (hereinafter referred to as Kaifeng DEAR air separation) and Gansu
Albums of Emergency shutdown of air separation unit
More
Solutions of Emergency shutdown of air separation unit
More
Large air separation plant KDON-20000/20000 solution for metallurgical industry
DEAR air separation has cooperated with customers in metallurgical industry domestic and abroad in many projects, and has rich project experience. DEAR has continuously invested in the research and development of large-scale air separation plant. In view of metallurgical industry, DEAR combined with the characteristic of this industry, develops high-efficiency energy-saving air separation plant, to meet the needs of large and medium customers. DEAR air separation uses the rapid development of internet technology to establish a remote monitoring system to collect real-time operation data of each air separation plant, and provides the best suggestions for users by using big data analysis.
Small air separation plant KDON (Ar)-4000/4000-110 solution for metallurgical industry
Metallurgical industry is an industry that exploits metal mineral resources and produces raw materials of various metal products, which is closely related to the national economy and people's livelihood. At present, Chinese iron and steel industry still has the situation of low concentration, insufficient capacity of high-end products and serious surplus of low-end products. DEAR air separation has provided a number of complete solutions for the metallurgical industry for many years, accumulated rich experience and helped the efficient development of the metallurgical industry. With years of service experience in the metallurgical industry, the small air separation plant KDON (Ar) - 4000 / 4000-110 cooperated by DEAR air separation and customers provides air separation plant with mature technology, stable equipment working condition, excellent performance and energy saving intelligence, which is highly recognized by customers.
Faq of Emergency shutdown of air separation unit
More
During the start-up phase, when the liquid volume accumulates in the condensing evaporator, the gas and liquid mixture will pass through the liquid air and liquid nitrogen throttle valves. When the throttle valve begins to close, due to the large opening of the valve, when the amount of gas and liquid mixture from the lower column to the upper column changes little, and the pressure of the lower column does not increase significantly, it means that the temperature difference of the condensing evaporator has not increased. At this time, the condensing evaporator and the surrounding insulation have been cooled to the low temperature required by the liquid accumulation stage. Due to a large amount of cold production and a large amount of gas liquefaction, the liquid evaporation in the condensing evaporator is also increased. The rising steam produced prevents the flow of liquid from the sieve plate hole, and gradually accumulates liquid on the tray, so the liquid level will drop. In ad
Nov 13, 2020
The load regulation range of low pressure air separation unit is related to the regulating performance of feed air compressor, the regulating performance of expander and the structural characteristics of distillation column. At present, the flow regulation range of turbine air compressor with inlet guide vane is 75% to 100%, and that of turbocharged expander with adjustable nozzle is 65% to 100%. Next, the most important thing is to adjust the residual of the distillation column. At present, the load regulation range of distillation column with structured packing can reach 50% - 100%, while that of traditional sieve tray column is 70% - 100%. If the load is too low, it will cause liquid leakage because the speed of steam passing through the sieve is too slow. When oxygen is sufficient and the oxygen output needs to be reduced, first reduce the output of oxygen products, then reduce the air flow accordingly, and adjust the expansion air volume according to the main cooling level. The
Nov 13, 2020