How to blast and purge the pressure pipe

How to blast and purge the pressure pipe
Apr 15, 2026
Author: DEAR AST

Steel pipes shall be flushed and purged as required after passing the strength test and before the pneumatic tightness test.

For many years, water flushing, air purging, steam purging and other technologies have been mainly used for flushing and purging. This is more effective for small-diameter pipelines. For pipelines with larger diameters, the ideal purging effect is often not achieved because the flow rate of purging medium cannot meet the specified requirements. As the pipeline accessories and instruments become more and more advanced, and the requirements of production technology continue to improve, some construction technologies can no longer meet the construction requirements. In the purging and flushing construction of large-diameter steel pipelines, the blasting purging method is replacing other construction methods used in the past.

Blasting purging is to close one end of the purged pipe with a bursting disc whose strength is much lower than that of the pipe, and inject compressed air into the other end. The air pressure in the system gradually increases. When the pressure exceeds the limit pressure that the bursting disc can bear, the bursting disc will suddenly rupture, and the compressed air in the system will instantly expand rapidly and eject from the bursting opening at a very high speed. At the same time, the welding slag and other sundries in the pipeline will also be discharged under the vibration caused by blasting and the impact of high-speed air flow. Repeated several times, the purging requirements can be achieved.  

The production of air separation equipment and oxygen pipelines of Deere air separation plant strictly comply with the requirements of process technical specifications, and the production and installation of pipelines ensure the high quality requirements of the overall air separation plant.

DEAR Air Separation Solve YourHow to blast and purge the pressure pipeYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top