Introduction of nitrogen plug factors in crude argon Tower

Introduction of nitrogen plug factors in crude argon Tower
Oct 12, 2023
Author: DEAR AST
Question Reply

Crude argon TowerIn normal operation, sometimes resistance drop, argon content drop and oxygen content increase of crude argon will suddenly occur, and normal operation condition of crude argon tower will be destroyed, it is called "nitrogen plug" working condition of crude argon tower. The direct reason for the "nitrogen plug" of the crude argon Tower is that the nitrogen content of the argon distillation in the upper tower exceeds, and generally the nitrogen content should not exceed 0.1%. This is because the separation of oxygen and argon is conducted in the crude argon Tower, and most of the oxygen in the argon distillation is condensed in the rising process, while the nitrogen component of low boiling point is not condensed, and all of them are left in the crude argon, making the nitrogen content in the crude argon be dozens of times larger than that in the argon distillation.
The heat transfer temperature difference of the crude argon Tower condenser is generally designed according to the nitrogen content of the crude argon which is 1.5%. If the content of the crude argon increases greatly, the temperature difference of the crude argon Tower condenser will be reduced, or even zero, in this way, the condensation of crude argon decreases or even does not condense, which will reduce the extraction of argon distillation and lower the flow rate of rising gas, causing leakage of the tower plate and finally leading to the failure of the crude argon tower to work normally. Once the "nitrogen plug" of the crude argon tower occurs, the blowing-off valve on the crude argon pipeline should be opened quickly first, so that the nitrogen gathered on the condensing side of the condenser of the crude argon tower can be discharged into the atmosphere quickly, then adjust the operating condition of the upper tower to make the nitrogen content of argon fraction gradually return to normal condition, and re-establish the crude argon column to return to normal rectification condition.

DEAR Air Separation Solve YourIntroduction of nitrogen plug factors in crude argon TowerYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The air cooling tower is the core equipment of the air separation precooling system, which is mainly used to cool and wash the high-temperature compressed air discharged from the air compressor, provide qualified low-temperature gas source for subsequent molecular sieve purification and cold box rectification, and ensure the stable operation of the whole unit. The air cooling tower adopts the countercurrent packing heat exchange structure, the tower is filled with high-efficiency packing, and the top is equipped with a spray device and a wire mesh demister. During operation, the high-temperature compressed air at 80 to 100 ℃ discharged by the air compressor enters from the bottom of the tower and flows from bottom to top; The cooling water is the normal temperature make-up water and the low-temperature chilled water prepared by the water-cooling tower, which is sprayed from top to bottom from the tower top, and the air and water are fully contacted in reverse for heat exchange. Under t
2026.11.12
Regulation of liquid nitrogen throttle valveThe opening of the liquid nitrogen throttle valve not only affects the reflux ratio of the upper tower, but also affects the reflux ratio of the lower tower. When the opening is increased, the reflux ratio of the upper tower increases, while the reflux ratio of the lower tower decreases, the purity of the nitrogen in the upper tower increases, and the purity of the oxygen enriched night sky in the lower tower increases. However, after the opening is over, the purity of the liquid nitrogen decreases, and the reduction of the reflux ratio of the upper tower is also detrimental to the improvement of the purity of the liquid oxygen. Therefore, an equilibrium point should be found for the opening of the liquid nitrogen throttle valve. We can generally use the purity difference between liquid nitrogen and gas nitrogen to judge whether the opening is appropriate. Generally, the purity of the sprayed liquid nitrogen is equal to that of the upper towe
2026.11.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top