Introduction of nitrogen plug factors in crude argon Tower

Introduction of nitrogen plug factors in crude argon Tower
Oct 12, 2023
Author: DEAR AST
Question Reply

Crude argon TowerIn normal operation, sometimes resistance drop, argon content drop and oxygen content increase of crude argon will suddenly occur, and normal operation condition of crude argon tower will be destroyed, it is called "nitrogen plug" working condition of crude argon tower. The direct reason for the "nitrogen plug" of the crude argon Tower is that the nitrogen content of the argon distillation in the upper tower exceeds, and generally the nitrogen content should not exceed 0.1%. This is because the separation of oxygen and argon is conducted in the crude argon Tower, and most of the oxygen in the argon distillation is condensed in the rising process, while the nitrogen component of low boiling point is not condensed, and all of them are left in the crude argon, making the nitrogen content in the crude argon be dozens of times larger than that in the argon distillation.
The heat transfer temperature difference of the crude argon Tower condenser is generally designed according to the nitrogen content of the crude argon which is 1.5%. If the content of the crude argon increases greatly, the temperature difference of the crude argon Tower condenser will be reduced, or even zero, in this way, the condensation of crude argon decreases or even does not condense, which will reduce the extraction of argon distillation and lower the flow rate of rising gas, causing leakage of the tower plate and finally leading to the failure of the crude argon tower to work normally. Once the "nitrogen plug" of the crude argon tower occurs, the blowing-off valve on the crude argon pipeline should be opened quickly first, so that the nitrogen gathered on the condensing side of the condenser of the crude argon tower can be discharged into the atmosphere quickly, then adjust the operating condition of the upper tower to make the nitrogen content of argon fraction gradually return to normal condition, and re-establish the crude argon column to return to normal rectification condition.

DEAR Air Separation Solve YourIntroduction of nitrogen plug factors in crude argon TowerYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Fluid resistance refers to the pressure drop of fluid flowing through pipes, valves or equipment. The actual process pressure gradually decreased. In order to ensure the final pressure required by the process, a pressure source (gas compressor or pump) is needed to provide higher pressure, that is, more energy is consumed. Therefore, the amount of resistance reflects the amount of energy loss. In oxygen production, flow resistance is also closely related to the production process. For example, the resistance measurement of switching heat exchanger is the basis to judge whether self-cleaning is good. If the resistance of the distillation column is too large, the normal distillation conditions will be destroyed. The magnitude of resistance (i.e. energy loss) can be expressed by the pressure drop before and after the fluid flows through the vessel. For example, the gauge pressure at the bottom of the tower is 0.038 MPa, the gauge pressure at the top of the tower is 0.025 MPa, and the p
2026.08.10
Problems in the process of pressure swing adsorption of Biogas
2026.08.07
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top