What issues should be paid attention to when operating the molecular sieve purification system of the air separation equipment

What issues should be paid attention to when operating the molecular sieve purification system of the air separation equipment
Oct 11, 2023
Author: DEAR AST

The purification effect of the molecular sieve purification system affects the operating cycle of the device. Improper operation of the same equipment may also affect the purification effect. The following issues should be noted during operation:

1) Installation requirements for molecular sieve adsorbers: carefully check whether the upper and lower sieve screens are damaged and whether they are firmly fixed; Whether the molecular sieve is fully filled and leveled; Carefully seal the inner and outer cylinder manholes to prevent mutual gas leakage;

2) When the molecular sieve adsorber is running, it is necessary to regularly monitor the temperature curve of the molecular sieve and the carbon dioxide content at the outlet to determine whether the adsorber is working properly;

3) Closely monitor the switching program of the adsorber and whether the switching pressure difference is normal. If there is a malfunction, it should be dealt with promptly;

4) Pay close attention to the normal operation of the refrigerator. If a short-term malfunction causes an increase in air outlet temperature, the switching cycle of the adsorber should be shortened in a timely manner and the malfunction should be eliminated in a timely manner;

5) When starting and boosting the air compressor, it should be done slowly to prevent excessive air velocity. When inflating the low-temperature system or increasing the system load (starting the expander, opening the throttle valve, etc.), it should be done slowly to prevent system pressure fluctuations;

6) When the air separation equipment is stopped, the main air valve behind the adsorber should be immediately closed to prevent excessive airflow velocity from impacting the molecular sieve bed layer during restart.

DEAR Air Separation Solve YourWhat issues should be paid attention to when operating the molecular sieve purification system of the air separation equipmentYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Why is the cryogenic air separation air compression system the most power consuming link?
2026.03.23
Screw compressor is a positive displacement compressor from the mechanical type, which is composed of the driving rotor and driven rotor, the main body and a pair of synchronous gears. Therefore, the common faults of screw compressor are as follows: 1. The bearing is burnt out. Because of the foreign matter in the oil system, the oil pressure and the quality of the oil are reduced, resulting in the bearing burning out. The main treatment methods are: check the oil supply system; clean the oil filter and the cooling pipe of the oil cooler; check and adjust the oil pressure regulating valve; test the oil quality, and replace the oil when it is not good; check and deal with the oil leakage points. 2. The rotor is burnt out. When foreign matters enter into the compressed medium system, the temperature of the rotor rises, the temperature of the cooling oil of the rotor increases due to the high temperature of the inhaled medium, and the compression ratio increases, which may cause the
2026.03.20
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top