What issues should be paid attention to when operating the molecular sieve purification system of the air separation equipment

What issues should be paid attention to when operating the molecular sieve purification system of the air separation equipment
Oct 11, 2023
Author: DEAR AST

The purification effect of the molecular sieve purification system affects the operating cycle of the device. Improper operation of the same equipment may also affect the purification effect. The following issues should be noted during operation:

1) Installation requirements for molecular sieve adsorbers: carefully check whether the upper and lower sieve screens are damaged and whether they are firmly fixed; Whether the molecular sieve is fully filled and leveled; Carefully seal the inner and outer cylinder manholes to prevent mutual gas leakage;

2) When the molecular sieve adsorber is running, it is necessary to regularly monitor the temperature curve of the molecular sieve and the carbon dioxide content at the outlet to determine whether the adsorber is working properly;

3) Closely monitor the switching program of the adsorber and whether the switching pressure difference is normal. If there is a malfunction, it should be dealt with promptly;

4) Pay close attention to the normal operation of the refrigerator. If a short-term malfunction causes an increase in air outlet temperature, the switching cycle of the adsorber should be shortened in a timely manner and the malfunction should be eliminated in a timely manner;

5) When starting and boosting the air compressor, it should be done slowly to prevent excessive air velocity. When inflating the low-temperature system or increasing the system load (starting the expander, opening the throttle valve, etc.), it should be done slowly to prevent system pressure fluctuations;

6) When the air separation equipment is stopped, the main air valve behind the adsorber should be immediately closed to prevent excessive airflow velocity from impacting the molecular sieve bed layer during restart.

DEAR Air Separation Solve YourWhat issues should be paid attention to when operating the molecular sieve purification system of the air separation equipmentYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquid air level in the lower column is one of the core parameters of air separation distillation, and its fluctuation directly affects the product purity and system stability. The causes of liquid level fluctuation can be summarized into four categories: gas source disturbance, valve failure, instrument distortion and abnormal working conditions in the tower. 1、 Inlet gas volume and pressure fluctuation. This is the most common cause. Unstable exhaust pressure of air compressor and sudden reduction of gas volume during switching of molecular sieve adsorber will lead to fluctuation of air volume entering the tower. The lower tower is very sensitive to the change of gas volume, and the liquid level will fluctuate immediately. In addition, the abnormal working condition of the booster or the adjustment of the expander gas volume will also indirectly disturb the liquid level of the lower tower through the cooling capacity balance. 2、 Valve regulating system failure. The liquid air thr
2026.10.28
In the operation of the air separation unit, the superheat of the expanded air sent to the upper column is a key parameter affecting the stability of distillation conditions and product purity. The fluctuation of superheat will directly change the gas-liquid load and mass transfer efficiency of the upper column, and then affect the distillation effect and energy consumption of the unit. If the superheat of the expanded air is too high, the gas entering the upper tower will carry a large amount of excess heat, which will significantly increase the gas phase temperature in the tower and aggravate the consumption of cooling capacity in the tower. This will lead to the decrease of reflux ratio in the distillation section of the upper column, insufficient gas-liquid two-phase contact, and poor mass transfer and heat transfer efficiency. At the same time, the increase of superheated gas will raise the rising gas flow in the tower and destroy the balance of distillation conditions, resulting
2026.10.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top