Why should the switching cycle be shortened during the start-up phase of the full low pressure air separation plant with self-oil removal process?

Why should the switching cycle be shortened during the start-up phase of the full low pressure air separation plant with self-oil removal process?
Mar 01, 2024
Author: DEAR AST
Question Reply

As we know, full low voltageAir separation equipmentIn order to ensure self-cleaning, the temperature difference at the cold end of the switching heat exchanger must be controlled within the allowable temperature difference range to ensure self-cleaning. The self-clearing temperature difference of the cold end is the temperature difference between the positive air passing through the section of the cold end and the return air passing through this section. In normal operation, the measured temperature difference at the cold end is self-cleaning temperature difference. But in the start-up phase of the air separation unit, the switching typeHeat exchangerThe temperature decreases with time, and the self-clearing temperature difference of the temperature that the positive return gas flows through the channel is far greater than the measured temperature difference of the cold end. In addition, with the extension of switching time and the acceleration of temperature drop, the temperature difference of self-clearing at the cold end will be enlarged. Therefore, in the start-up stage of the air separation unit, with the cooling of the switching heat exchanger, in order to ensure self-cleaning, the switching period must be shortened.
The shortening of switching cycle is beneficial to the removal of frozen water and carbon dioxide. But at this time, the loss of air switching is relatively large.
As for the cooling accumulator, because it is a cold accumulator heat exchanger, the shorter the switching time is, the smaller the temperature difference at the cold end will be. Moreover, the amount of water and carbon dioxide frozen will be reduced, and the frozen layer will be thin, it is easier to clear.
In short, inAir separation equipmentDuring the start-up, shortening the switching cycle is an effective measure to ensure the self-cleaning of the switching heat exchanger.

DEAR Air Separation Solve YourWhy should the switching cycle be shortened during the start-up phase of the full low pressure air separation plant with self-oil removal process?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the principle of the deep cooling method of air separation?
2024.04.26
What are the reasons why the main cooling liquid level of the air separation equipment is not high and how to solve it?
2024.04.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top