What role does the expansion heat exchanger play and where should it be placed?

What role does the expansion heat exchanger play and where should it be placed?
Feb 29, 2024
Author: DEAR AST
Question Reply

On the one hand, the expansion heat exchanger is to reduce the temperature of the air after expansion by utilizing the cooling amount of the sewage nitrogen returned from the upper tower, so as to reduce the superheat of the air after expansion into the upper tower; on the other hand, it plays a role in distributing the cooling capacity of the upper and lower towers. Through it, the cooling amount of dirty nitrogen from the outlet supercooler to the switch-type heat exchanger (or the cooler) is partly returned to the upper tower, which improves the rectification of the upper tower.
The location of the expansion heat exchanger can be placed in front of or behind the expansion machine, which is determined by the process design. China'sLarge air separation plantUsually set in front of the machine, use a part of the dirt nitrogen of the supercooler to cool the air in front of the expansion machine, makingExpanderThe temperature after it is not too high, which solves the problem of superheat when the air enters the tower. The disadvantage of this setting is that the temperature drop before the expansion machine will lead to the problem of reduction of unit refrigerating capacity (unit enthalpy drop) of the expansion machine.
In the introduction of largeAir separation equipmentThere are also those that place the expansion heat exchanger behind the machine. This arrangement is suitable for the situation that the length of the plate unit of the switching heat exchanger increases, the circulation temperature increases, and the temperature in front of the expansion machine increases. The increase of the temperature before the machine can increase the refrigerating capacity per unit of the expansion machine and reduce the expansion air volume entering the upper tower; and the heat exchanger after the machine can reduce the superheat of the expansion air entering the upper tower, both of them are beneficial to the rectification of the upper tower, and the disadvantage is that the back pressure after expansion increases slightly. But because the resistance of Plate-fin Heat Exchanger is not big, it has little influence on enthalpy drop of expansion machine.
Due to the setting of expansion heat exchanger, the moisture content of the air in the lower tower is reduced, which can improve the purity of the liquid space and also benefit the rectification of the tower.

DEAR Air Separation Solve YourWhat role does the expansion heat exchanger play and where should it be placed?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top