1, gas welding of purple copper plate: welding purple copper plate is most commonly used for butt joints, lap joints and ding joints are used as little as possible. Gas welding can be used in two kinds of welding wire, one containing deoxidizing elements, such as wire 201, 202; the other is the general purple copper wire and the cutting strip of the parent material, using gas 301 as flux. Gas welding purple copper should be used when the neutral flame.

2, manual arc welding of purple copper: in manual arc welding using purple copper electrode copper 107, the core is purple copper (T2, T3). Before welding should clean up the edges of the weld. Weld thickness greater than 4 mm, must be preheated before welding, preheating temperature is generally around 400 ~ 500 ℃. Welding with copper 107 welding rod, the power supply should be used DC reverse connection.

3, copper plate manual argon arc welding: in the purple copper plate manual argon arc welding, the use of welding wire are: wire 201 (special purple copper welding wire) and wire 202, also using purple copper wire, such as T2. Before welding should be welded edge of the workpiece and wire surface oxidation film, oil and other dirt must be cleaned up to avoid the production of porosity, slag and other defects. The methods of cleaning in small air separation unit are mechanical cleaning method and chemical cleaning method.

Dear Air Separation has been adhering to the quality service, solve the customer's worries, think about the customer's thoughts. Pre-sales business support, in-sales project implementation, to after-sales attentive service, the three links interlocked, seamless, to establish a perfect service closed matrix.

24836196B8833A0945BBE37D57EAB25E

DEAR Air Separation Solve YourCopper plate welding methods in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The air cooling tower is the core equipment of the air separation precooling system, which is mainly used to cool and wash the high-temperature compressed air discharged from the air compressor, provide qualified low-temperature gas source for subsequent molecular sieve purification and cold box rectification, and ensure the stable operation of the whole unit. The air cooling tower adopts the countercurrent packing heat exchange structure, the tower is filled with high-efficiency packing, and the top is equipped with a spray device and a wire mesh demister. During operation, the high-temperature compressed air at 80 to 100 ℃ discharged by the air compressor enters from the bottom of the tower and flows from bottom to top; The cooling water is the normal temperature make-up water and the low-temperature chilled water prepared by the water-cooling tower, which is sprayed from top to bottom from the tower top, and the air and water are fully contacted in reverse for heat exchange. Under t
2026.11.12
Regulation of liquid nitrogen throttle valveThe opening of the liquid nitrogen throttle valve not only affects the reflux ratio of the upper tower, but also affects the reflux ratio of the lower tower. When the opening is increased, the reflux ratio of the upper tower increases, while the reflux ratio of the lower tower decreases, the purity of the nitrogen in the upper tower increases, and the purity of the oxygen enriched night sky in the lower tower increases. However, after the opening is over, the purity of the liquid nitrogen decreases, and the reduction of the reflux ratio of the upper tower is also detrimental to the improvement of the purity of the liquid oxygen. Therefore, an equilibrium point should be found for the opening of the liquid nitrogen throttle valve. We can generally use the purity difference between liquid nitrogen and gas nitrogen to judge whether the opening is appropriate. Generally, the purity of the sprayed liquid nitrogen is equal to that of the upper towe
2026.11.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top