How to adjust the cooling capacity of air separation unit?

How to adjust the cooling capacity of air separation unit?
Mar 09, 2026
Author: DEAR AST

The adjustment of cold production of air separation unit shall be realized through multi-link cooperative operation, and the core is to balance the supply and demand relationship of cold production of the system.
Dynamic adjustment of expander: rotate the nozzle blade to change the gas flow sectional area. When the opening increases, the expansion air volume increases and the refrigerating capacity increases accordingly; On the contrary. The inlet pressure is controlled by adjusting the opening of the throttle valve in front of the expander. The decrease of the pressure will reduce the gas expansion ratio, thus reducing the refrigerating capacity.
Linkage control of rectification working condition: when the main cooling liquid level is too high, reduce the expansion air volume to avoid deterioration of rectification working condition; On the contrary, the expansion shall be increased in case of insufficient cooling capacity. The reflux liquid amount of the lower column is controlled by the liquid nitrogen throttle valve, which indirectly affects the rectification potential of the upper column, and then regulates the cooling demand.
System pressure and temperature management: appropriately turn down the oxygen and nitrogen supply valves to increase the low and medium pressure and reduce the refrigerating capacity; Conversely, decreasing the pressure increases the cold generation. Regulate the cooling water flow of air compressor to change the inlet temperature of high pressure air. In addition, open the blow off valve at the bottom of the heat exchanger to discharge the subcooled liquefied air and assist in regulating the cooling capacity.
Cooling capacity consumption and balance: when the cooling capacity is excessive, part of the cooling capacity consumed by liquid oxygen can be discharged, but it shall be ensured that the liquid oxygen surface is not lower than the safe value. Regularly check the heat transfer efficiency of the heat exchanger to avoid the loss of cooling capacity caused by the expansion of temperature difference at the hot end; At the same time, the multistage expansion system can be used for cooling in stages to reduce heat loss.
The cooling capacity shall be adjusted slowly and carefully to avoid the violent fluctuation of parameters affecting the rectification working condition. Key parameters such as main cooling liquid level and oxygen purity shall be monitored synchronously during operation to ensure stable operation of the system.

DEAR Air Separation Solve YourHow to adjust the cooling capacity of air separation unit?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top