当前位置: Home / Faq / Liquefied air separation FAQ /

What is self-cleaning? Why can we use the self-cleaning method to clear the moisture and carbon dioxide in the air?

What is self-cleaning? Why can we use the self-cleaning method to clear the moisture and carbon dioxide in the air?
Oct 27, 2023
Author: DEAR AST
Question Reply

The air passes through the cooler or the switching heat exchanger. As the temperature decreases continuously, the moisture gradually flows out and deposits on the stuffing of the cooler or the fin of the plate heat exchanger in the form of water drops, snowflakes, etc, there is basically no water in the gas at-60℃. When the air temperature drops below-130℃, carbon dioxide is also gradually precipitated in the form of solid (dry ice), and there is basically no carbon dioxide when it reaches-170℃. The precipitation and freezing of moisture and carbon dioxide in the air in the switching heat exchanger provide good conditions for the safe and reliable operation of the air separation plant. But it has a negative effect on heat transfer, and it will also block channels and increase flow resistance. Therefore, these eluates should be removed timely and regularly. The method adopted is to take away the deposited water and carbon dioxide when the backflow gas (such as dirt nitrogen) passes through, so it is called "self-cleaning ".
Why can the backflow of sewage nitrogen take away the frozen water and carbon dioxide? This is because fromDistillation columnThe dirt nitrogen from the upper tower is basically the unsaturated gas without moisture and carbon dioxide, so moisture and carbon dioxide can be evaporated and sublimated (from liquid or solid to gas ), enter the dirty nitrogen. Although the temperature of the polluted nitrogen is lower than that of the normal air, the maximum content (saturation content) of water and carbon dioxide that can be contained in every cubic meter of the backflow polluted nitrogen is less than that brought in by the normal air, however, since the pressure of dirt nitrogen is much lower than that of the forward air, the actual volume flow is 3 ~ larger than that of the forward air ~ 4 times, so the actual capacity of water and carbon dioxide that can be contained is larger than that in the positive flow, which is possible to clean up all the deposited water and carbon dioxide to achieve the purpose of self-cleaning.

DEAR Air Separation Solve YourWhat is self-cleaning? Why can we use the self-cleaning method to clear the moisture and carbon dioxide in the air?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquid air separation plant system uses the cold energy to produce liquid oxygen, liquid nitrogen and liquid argon in an air separation system, including an air compression pre-cooling system, an air purification system, an air separation system and a nitrogen circulation system for liquid air separation plant cold recovery. the nitrogen circulation system for liquid air separation plant cold recovery is placed in a separate cold box from the main cold box of the air separation system. the l...
2026.08.03
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top