当前位置: Home / Faq / Liquefied air separation FAQ /

What is self-cleaning? Why can we use the self-cleaning method to clear the moisture and carbon dioxide in the air?

What is self-cleaning? Why can we use the self-cleaning method to clear the moisture and carbon dioxide in the air?
Oct 27, 2023
Author: DEAR AST
Question Reply

The air passes through the cooler or the switching heat exchanger. As the temperature decreases continuously, the moisture gradually flows out and deposits on the stuffing of the cooler or the fin of the plate heat exchanger in the form of water drops, snowflakes, etc, there is basically no water in the gas at-60℃. When the air temperature drops below-130℃, carbon dioxide is also gradually precipitated in the form of solid (dry ice), and there is basically no carbon dioxide when it reaches-170℃. The precipitation and freezing of moisture and carbon dioxide in the air in the switching heat exchanger provide good conditions for the safe and reliable operation of the air separation plant. But it has a negative effect on heat transfer, and it will also block channels and increase flow resistance. Therefore, these eluates should be removed timely and regularly. The method adopted is to take away the deposited water and carbon dioxide when the backflow gas (such as dirt nitrogen) passes through, so it is called "self-cleaning ".
Why can the backflow of sewage nitrogen take away the frozen water and carbon dioxide? This is because fromDistillation columnThe dirt nitrogen from the upper tower is basically the unsaturated gas without moisture and carbon dioxide, so moisture and carbon dioxide can be evaporated and sublimated (from liquid or solid to gas ), enter the dirty nitrogen. Although the temperature of the polluted nitrogen is lower than that of the normal air, the maximum content (saturation content) of water and carbon dioxide that can be contained in every cubic meter of the backflow polluted nitrogen is less than that brought in by the normal air, however, since the pressure of dirt nitrogen is much lower than that of the forward air, the actual volume flow is 3 ~ larger than that of the forward air ~ 4 times, so the actual capacity of water and carbon dioxide that can be contained is larger than that in the positive flow, which is possible to clean up all the deposited water and carbon dioxide to achieve the purpose of self-cleaning.

DEAR Air Separation Solve YourWhat is self-cleaning? Why can we use the self-cleaning method to clear the moisture and carbon dioxide in the air?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant cold energy utilises air separation equipment, generally large air separation equipment with 2 combined expanders. The price is around 4 million RMB. The expansion air in the air separation plant is no longer required, so for the internal compression process air separation, the inlet air volume of the circulating booster is reduced by about 40% (from 5.A-2A). The energy consumption of the booster is reduced and the investment is reduced. Liquid air separation equipmen...
2026.06.18
1.In the process of preparation and implementation of hoisting construction, the safety and quality assurance system must ensure the normal operation,to ensure that the hoisting project meets the requirements of safety and quality. Before hoisting, safety and quality inspection must be carried out, and it must comply with the code forLifting construction of chemical engineering construction (HG20201-2000) and other regulations and specifications. 2.The crane performance shall meet the requirements of hoisting process, and the alarm and hydraulic system must be reliable. 3.Strictly implement the provisions of the technical documents attached to the crane. 4.The hoisting schedule of auxiliary crane should match that of main crane. 5.The hook deflection angle shall not be greater than 3°. 6.It is forbidden to drag the unitdirectly on the ground with crane. 7.Before unithoisting, trial hoisting shall be carried out. The clear hoisting distance and the foundation change at
2026.06.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top