What problems should be paid attention to in the process of storage and transportation of liquid storage tank?

What problems should be paid attention to in the process of storage and transportation of liquid storage tank?
Sep 22, 2022
Author: DEAR AST
问题回复

In the process of storage and transportation, the liquid storage tank should pay attention:
1) the protective equipment and instrument of storage tank should be in good condition;
2) the storage tank should be well ventilated during the process of storage and transportation, and inflammable materials should not be stored around without any fire;
3) the filling rate of the storage tank is less than 95%, and overcharging and overpressure are forbidden;
4) when there is liquid in the storage tank, hot repair is strictly prohibited;
5)EquipmentThe pipeline thawing should be heated slowly, do not use overheated working medium or open fire to freeze;
6) wear protective gloves when touching low temperature liquid to avoid direct contact between skin and low temperature liquid;
7) during the transportation process, it should be smooth and there should be no big turbulence.

DEAR Air Separation Solve YourWhat problems should be paid attention to in the process of storage and transportation of liquid storage tank?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top