Air compressorIt is one of the main mechanical power equipment of many enterprises, so it is very necessary to keep the safe operation of air compressor. Strictly implementing the operation specification of the air compressor not only helps to prolong the service life of the air compressor, but also ensures the safety of the operators of the air compressor. Now let's learn about the operation specification of the air compressor.

I. Before operating the air compressor, we should pay attention to the following problems:

1. Keep the lubricating oil in the oil tank within the scale range. Before the operation of the air compressor, check that the amount of oil in the oiling machine should not be lower than the scale value.

2. Check whether the moving parts are flexible, whether the connecting parts are fastened, whether the lubrication system is normal, and whether the motor and electrical control equipment are safe and reliable.

3. Before the operation of the air compressor, check whether the protective devices and safety accessories are intact and complete.

4. Check whether the exhaust pipe is unblocked.

5. Connect the water source and open each water inlet valve to make the cooling water unblocked.

II. When operating the air compressor, attention should be paid to the first starting after a long period of service, and the turning wheel must be checked. Attention should be paid to whether there are phenomena such as impact, jam or abnormal sound, etc. Imported pumps

III. The machine must be started under the condition of no load. After the condition of no-load operation is normal, the air compressor will enter the load operation step by step.

IV. During the operation of air compressor, after normal operation, all kinds of instrument reading should be paid attention to frequently and be adjusted at any time.

V. During the operation of air compressor, the following conditions should also be checked:

1. Whether the motor temperature is normal, and whether the reading of each electric meter is within the specified range.

2. Whether the running sound of each machine part is normal.

3. Whether the suction valve cover is hot, and whether the sound of the valve is normal.

4. Whether all kinds of safety protection equipments of air compressor are reliable.

6. After 2 hours of operation of the air compressor, the oil and water in the oil-water separator, intermediate cooler and post cooler should be discharged once, and the oil and water in the air storage barrel should be discharged once per shift.

VII. When the following situations are found in the operation of air compressor, stop the car immediately, find out the reasons and eliminate them.

1. Final break of lubricating oil or final break of cooling water.

2. The water temperature suddenly rises or falls.

3. The exhaust pressure suddenly rises and the safety valve fails.

4. The load suddenly exceeds the normal value.

5. Abnormal mechanical noise.

6. The motor or electrical equipment is abnormal.

DEAR Air Separation Solve YourCorrect operation method of air compressorYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top