How to operate the all-low-voltage capturing machine when it encounters emergency power failure?

How to operate the all-low-voltage capturing machine when it encounters emergency power failure?
Sep 19, 2022
Author: DEAR AST
Question Reply

Full low pressure oxygen generatorIn case of emergency power failure, the first task is to open the air release valve at the end of the air compressor and close the valve that air enters the distillation column quickly, in case that the air compressor reverses compressed air and burns the bearing because of the failure of the outlet check valve of the air compressor. Follow these steps:
1) turn the switching mechanism from automatic to manual, and close the forced Valve and average pressure switching valve of air entering the tower. Open the sewage nitrogen vent valve.
2) cut off the solenoid valve of the expansion machine, and close the inlet regulating valve of the expansion machine and the inlet and outlet valves of the expansion machine.
3) close the regulating valve of liquid, liquid nitrogen and sewage nitrogen.
4) turn off all the oxygen and nitrogen products and send them out of the valve, and open the vent valve, then put the three-way valve of dirt and nitrogen in the vent side.
5) turn off all the inflated air to enter the disc valve of the upper tower, and open the bypass valve.
6) close the oxygen regulating disc valve, and fully open the dirt nitrogen and pure nitrogen regulating disc valve.
7) turn off the steam gas source of the steam heater.
8) cut off the power switch of the electrical equipment and make it in the starting position.
After finding out the cause of the power failure and eliminating the failure, be ready to start the car.

DEAR Air Separation Solve YourHow to operate the all-low-voltage capturing machine when it encounters emergency power failure?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top