Question Reply

When the small oxygen generator uses liquid nitrogen throttle to adjust the purity of liquid nitrogen, it can be found that the valve is adjusted within a certain opening range, which has little effect on the purity of liquid nitrogen; while in a certain position, valve opening changes by 1 ° ~ 2 °, the purity of liquid nitrogen will change greatly. That is to say, the opening of liquid nitrogen throttle and the change of liquid nitrogen purity are not a simple proportional relationship, but the most sensitive position of adjustment.


This phenomenon has a lot to do with the structure of the top of the lower tower. The top of the lower tower is connected with the main cooling. Nitrogen rises into the main cooling tube and condenses into the liquid nitrogen downstream. The liquid nitrogen connection tank is set at the lower part of the main cooling. The liquid nitrogen in the liquid nitrogen tank flows to the top tower through the liquid nitrogen tube, and the condensate liquid nitrogen in the condensation tube in the inner circle of the liquid nitrogen tank will directly flow back to the bottom tower as the reflux liquid. When the opening of the liquid nitrogen throttle valve is too large and the liquid level in the liquid nitrogen tank is too low, the gas-liquid mixture will pass through the liquid nitrogen pipeline. At this time, the amount of liquid nitrogen condensing in the main cooling decreases correspondingly, the reflux fluid of the lower tower also decreases, so the purity of liquid nitrogen is relatively low.


When the small liquid nitrogen throttle is closed, the amount of vapour through the throttle will gradually decrease, the recirculation of the lower tower will increase, and the purity of liquid nitrogen will gradually increase. When the liquid nitrogen throttle is closed so small that no vapour has passed through the pipe, and the liquid nitrogen in the liquid nitrogen tank is not enough to overflow, even if the small liquid nitrogen throttle is closed, it will not change the amount of recirculation fluid of the lower tower. Therefore, the purity of liquid nitrogen basically remains unchanged. When the small throttle valve continues to be closed, so that all the liquid flowing into the liquid nitrogen tank cannot pass through the throttle valve, and when the liquid level rises to some overflows back to the lower tower, the recirculation fluid of the lower tower increases, the purity of liquid nitrogen will be greatly improved. Then turn off the small throttle, as the reflux fluid of the lower tower continues to increase, the purity of liquid nitrogen will continue to increase, but the change is slow, and there will be no mutation. In addition, if the amount of liquid nitrogen is too small and the purity of oxygen in liquid air is too low, it is also useless for rectification in the upper tower. During the operation, the purity of liquid nitrogen should be analyzed frequently to find out each air separation equipmentThe corresponding liquid nitrogen at the sensitive point of purity change throttle opening.

DEAR Air Separation Solve YourWhy does liquid nitrogen throttle have the most sensitive position to adjust liquid nitrogen purity?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked. The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons: 1. The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bed layer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger c
2026.03.30
What is the oxygen internal compression process
2026.03.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top