What are the reasons why the oxygen production fails to reach the index?

What are the reasons why the oxygen production fails to reach the index?
Apr 12, 2024
Author: DEAR AST
Question Reply

There are mainly the following factors that affect the output of oxygen:
1) insufficient processing air volume. Reasons for insufficient air capacity:
① The environment temperature is too high;
② The atmospheric pressure is too low;
③ The air suction filter is blocked;
④ If the voltage is too low or the grid frequency decreases, the rotating speed will decrease;
⑤ The cooling effect of intermediate cooler is not good;
⑥ Internal leakage exists between levels;
⑦ Air leakage of valve and pipeline, leakage of automatic valve or switch valve;
⑧ For the purification process of the molecular sieve, it may be the gas leakage of the butterfly valve switching.
2) the average purity of nitrogen is too low. The reasons are:
①Distillation columnReduction of board efficiency;
② Too much air expansion caused by too much cold loss;
③ The purity of liquid nitrogen is too low, and the amount of liquid nitrogen is too large;
④The amount of liquid nitrogen is too small;
⑤ Leakage of liquid air or liquid nitrogen supercooler;
⑥ The amount of nitrogen (or fraction) taken out is too large;
⑦ The opening degree of liquid air and liquid nitrogen regulating valve is improper, and the working condition of the lower tower is not well adjusted.
3) poor heat transfer of main cooling. The heat transfer surface of the main cooling is insufficient, or there are more non-condensing gases on the nitrogen side, which will affect the heat transfer of the main cooling and reduce the evaporation of liquid oxygen.
4) equipment resistance increases. Because the tower plate, liquid-air adsorber or supercooler is blocked, the opening of liquid-air and liquid-nitrogen throttle valve is too small or blocked, which will cause the pressure of the lower tower to rise and the air entering the tower to decrease. When the switching heat exchanger freezes, it will also cause the resistance of the system to increase and the air volume in the tower to decrease automatically.
5) oxygen pipelines and containers have leaks.

DEAR Air Separation Solve YourWhat are the reasons why the oxygen production fails to reach the index?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top