Why is the change of the main cooling liquid oxygen level the main sign to judge whether the cooling capacity of the oxygen generator is sufficient?

Why is the change of the main cooling liquid oxygen level the main sign to judge whether the cooling capacity of the oxygen generator is sufficient?
Jan 11, 2024
Author: DEAR AST
Question Reply

Air separation equipmentWhen the working condition is stable, the cooling capacity of the unit keeps balance with the cooling capacity consumption, and the temperature, pressure, liquid level and other parameters of each part in the unit no longer change with time. The main cooling is the bond connecting the upper tower and the lower tower. The rising nitrogen from the lower tower is heated and condensed in the main cooling, and the reflux liquid oxygen from the upper tower is absorbed and evaporated in the main cooling. When the amount of recirculation liquid is equal to the evaporation, the liquid level remains unchanged.
When the processed air enters the tower, it has certain "moisture content", that is, a small part of it is liquid. Most of the air will be liquefied in the main cooling. For low voltageAir separation equipment, The air entering the tower is composed of the air at the cold end of the main heat exchanger and the air through the liquid purifier; for medium pressureAir separation equipment, It is composed of the mixture of the expanded air and the throttle and depressurization air through the section-1 valve after the heat exchanger is discharged. Under normal circumstances, their comprehensive state of entering the tower has a certain "moisture content" (liquefaction rate ). The air condition of entering the tower isAir separation equipmentThe internal heat exchange system and cooling system are guaranteed.
When the cooling loss of the unit increases, the refrigerating capacity is insufficient, which reduces the air moisture content entering the tower. It is required that the amount of nitrogen condensing in the main cooling will increase, and the heat load of the main cooling will increase, correspondingly, the evaporation of liquid oxygen will also increase and the liquid oxygen surface will decrease; if the refrigerating capacity is too much, for example, when the working pressure of the medium pressure device is too high, the moisture content of the air going into the tower will increase and the heat load of the main cooling will decrease, when the evaporation of liquid oxygen decreases, the liquid oxygen surface will rise. Therefore, whether the cooling capacity of the unit is balanced or not should be reflected in the change of the main cold liquid surface first.
Of course, the main cooling liquid oxygen surface is the main sign of whether the cooling volume is balanced, not the only sign. Because the opening of the air throttle valve is too large or too small, it will change the liquid level of the lower tower, and then affect the change of the liquid oxygen level of the main cooling. However, this is not caused by the imbalance of cold volume, but by the improper distribution of liquid volume in the upper and lower towers, and the fluctuation of liquid level is also temporary.

DEAR Air Separation Solve YourWhy is the change of the main cooling liquid oxygen level the main sign to judge whether the cooling capacity of the oxygen generator is sufficient?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The air cooling tower is the core equipment of the air separation precooling system, which is mainly used to cool and wash the high-temperature compressed air discharged from the air compressor, provide qualified low-temperature gas source for subsequent molecular sieve purification and cold box rectification, and ensure the stable operation of the whole unit. The air cooling tower adopts the countercurrent packing heat exchange structure, the tower is filled with high-efficiency packing, and the top is equipped with a spray device and a wire mesh demister. During operation, the high-temperature compressed air at 80 to 100 ℃ discharged by the air compressor enters from the bottom of the tower and flows from bottom to top; The cooling water is the normal temperature make-up water and the low-temperature chilled water prepared by the water-cooling tower, which is sprayed from top to bottom from the tower top, and the air and water are fully contacted in reverse for heat exchange. Under t
2026.11.12
Regulation of liquid nitrogen throttle valveThe opening of the liquid nitrogen throttle valve not only affects the reflux ratio of the upper tower, but also affects the reflux ratio of the lower tower. When the opening is increased, the reflux ratio of the upper tower increases, while the reflux ratio of the lower tower decreases, the purity of the nitrogen in the upper tower increases, and the purity of the oxygen enriched night sky in the lower tower increases. However, after the opening is over, the purity of the liquid nitrogen decreases, and the reduction of the reflux ratio of the upper tower is also detrimental to the improvement of the purity of the liquid oxygen. Therefore, an equilibrium point should be found for the opening of the liquid nitrogen throttle valve. We can generally use the purity difference between liquid nitrogen and gas nitrogen to judge whether the opening is appropriate. Generally, the purity of the sprayed liquid nitrogen is equal to that of the upper towe
2026.11.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top