Why is the change of the main cooling liquid oxygen level the main sign to judge whether the cooling capacity of the oxygen generator is sufficient?

Why is the change of the main cooling liquid oxygen level the main sign to judge whether the cooling capacity of the oxygen generator is sufficient?
Jan 11, 2024
Author: DEAR AST
Question Reply

Air separation equipmentWhen the working condition is stable, the cooling capacity of the unit keeps balance with the cooling capacity consumption, and the temperature, pressure, liquid level and other parameters of each part in the unit no longer change with time. The main cooling is the bond connecting the upper tower and the lower tower. The rising nitrogen from the lower tower is heated and condensed in the main cooling, and the reflux liquid oxygen from the upper tower is absorbed and evaporated in the main cooling. When the amount of recirculation liquid is equal to the evaporation, the liquid level remains unchanged.
When the processed air enters the tower, it has certain "moisture content", that is, a small part of it is liquid. Most of the air will be liquefied in the main cooling. For low voltageAir separation equipment, The air entering the tower is composed of the air at the cold end of the main heat exchanger and the air through the liquid purifier; for medium pressureAir separation equipment, It is composed of the mixture of the expanded air and the throttle and depressurization air through the section-1 valve after the heat exchanger is discharged. Under normal circumstances, their comprehensive state of entering the tower has a certain "moisture content" (liquefaction rate ). The air condition of entering the tower isAir separation equipmentThe internal heat exchange system and cooling system are guaranteed.
When the cooling loss of the unit increases, the refrigerating capacity is insufficient, which reduces the air moisture content entering the tower. It is required that the amount of nitrogen condensing in the main cooling will increase, and the heat load of the main cooling will increase, correspondingly, the evaporation of liquid oxygen will also increase and the liquid oxygen surface will decrease; if the refrigerating capacity is too much, for example, when the working pressure of the medium pressure device is too high, the moisture content of the air going into the tower will increase and the heat load of the main cooling will decrease, when the evaporation of liquid oxygen decreases, the liquid oxygen surface will rise. Therefore, whether the cooling capacity of the unit is balanced or not should be reflected in the change of the main cold liquid surface first.
Of course, the main cooling liquid oxygen surface is the main sign of whether the cooling volume is balanced, not the only sign. Because the opening of the air throttle valve is too large or too small, it will change the liquid level of the lower tower, and then affect the change of the liquid oxygen level of the main cooling. However, this is not caused by the imbalance of cold volume, but by the improper distribution of liquid volume in the upper and lower towers, and the fluctuation of liquid level is also temporary.

DEAR Air Separation Solve YourWhy is the change of the main cooling liquid oxygen level the main sign to judge whether the cooling capacity of the oxygen generator is sufficient?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top