Why should the air separation tower be blown away and how should it be blown away correctly?

Why should the air separation tower be blown away and how should it be blown away correctly?
Oct 12, 2022
Author: DEAR AST
Question Reply

Blowing off is the operation of removing solid impurities and free water by the impact of airflow, and at the same time, it can also expel part of the heat and cold energy stored in the equipment. After installation and overhaulAir separation equipmentIt is easy to remain solid impurities and water drops, so it should be blown away; when the device is stopped, the cooling capacity of expelling part should be blown away, and after the heating operation, it should also be blown away to expel part of heat and further clear away water.
There are roughly two blowing methods: continuous blowing and intermittent blowing. The so-called "continuous blowing-off" is the blowing-off method that always opens the blowing-off valve and lasts for a period of time. The so-called "Intermittent blow-off" means that the blow-off valve is closed and open at the same time. When it is closed, it is opened suddenly after holding high pressure, and it is repeated. This method has better effect on removing solid impurities and free water. Because the pressure difference increases when the pressure is suffocated, the airflow speed increases when the blow-off valve is opened, and the impact clamping effect strengthens.
If the drying gas is not used in the blowing-off process, the water in the cold equipment will reach saturation, and the water may be precipitated in the equipment, and even the water will freeze and freeze the pipeline and equipment. Moreover, after blowing off, the remaining wet gas in the equipment is easy to elude water drops when the temperature changes. To reach the purpose of equipment drying, it is best to use dry airflow to blow off. For cold equipment, when the temperature does not rise to above 0℃, do not blow off with wet air.
The blowing-off procedure is to clean the pipes outside the tower first to prevent the impurity from entering the tower; in the tower, first blow the air heat exchanger, and then blow off the tower, finally, blow the tower and liquid oxygen and liquid nitrogen emission system.

DEAR Air Separation Solve YourWhy should the air separation tower be blown away and how should it be blown away correctly?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquid air level in the lower column is one of the core parameters of air separation distillation, and its fluctuation directly affects the product purity and system stability. The causes of liquid level fluctuation can be summarized into four categories: gas source disturbance, valve failure, instrument distortion and abnormal working conditions in the tower. 1、 Inlet gas volume and pressure fluctuation. This is the most common cause. Unstable exhaust pressure of air compressor and sudden reduction of gas volume during switching of molecular sieve adsorber will lead to fluctuation of air volume entering the tower. The lower tower is very sensitive to the change of gas volume, and the liquid level will fluctuate immediately. In addition, the abnormal working condition of the booster or the adjustment of the expander gas volume will also indirectly disturb the liquid level of the lower tower through the cooling capacity balance. 2、 Valve regulating system failure. The liquid air thr
2026.10.28
In the operation of the air separation unit, the superheat of the expanded air sent to the upper column is a key parameter affecting the stability of distillation conditions and product purity. The fluctuation of superheat will directly change the gas-liquid load and mass transfer efficiency of the upper column, and then affect the distillation effect and energy consumption of the unit. If the superheat of the expanded air is too high, the gas entering the upper tower will carry a large amount of excess heat, which will significantly increase the gas phase temperature in the tower and aggravate the consumption of cooling capacity in the tower. This will lead to the decrease of reflux ratio in the distillation section of the upper column, insufficient gas-liquid two-phase contact, and poor mass transfer and heat transfer efficiency. At the same time, the increase of superheated gas will raise the rising gas flow in the tower and destroy the balance of distillation conditions, resulting
2026.10.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top