当前位置: Home / Faq / Large air separation FAQ /

Why should the air separation tower be blown away and how should it be blown away correctly?

Why should the air separation tower be blown away and how should it be blown away correctly?
Oct 12, 2022
Author: DEAR AST
Question Reply

Blowing off is the operation of removing solid impurities and free water by the impact of airflow, and at the same time, it can also expel part of the heat and cold energy stored in the equipment. After installation and overhaulAir separation equipmentIt is easy to remain solid impurities and water drops, so it should be blown away; when the device is stopped, the cooling capacity of expelling part should be blown away, and after the heating operation, it should also be blown away to expel part of heat and further clear away water.
There are roughly two blowing methods: continuous blowing and intermittent blowing. The so-called "continuous blowing-off" is the blowing-off method that always opens the blowing-off valve and lasts for a period of time. The so-called "Intermittent blow-off" means that the blow-off valve is closed and open at the same time. When it is closed, it is opened suddenly after holding high pressure, and it is repeated. This method has better effect on removing solid impurities and free water. Because the pressure difference increases when the pressure is suffocated, the airflow speed increases when the blow-off valve is opened, and the impact clamping effect strengthens.
If the drying gas is not used in the blowing-off process, the water in the cold equipment will reach saturation, and the water may be precipitated in the equipment, and even the water will freeze and freeze the pipeline and equipment. Moreover, after blowing off, the remaining wet gas in the equipment is easy to elude water drops when the temperature changes. To reach the purpose of equipment drying, it is best to use dry airflow to blow off. For cold equipment, when the temperature does not rise to above 0℃, do not blow off with wet air.
The blowing-off procedure is to clean the pipes outside the tower first to prevent the impurity from entering the tower; in the tower, first blow the air heat exchanger, and then blow off the tower, finally, blow the tower and liquid oxygen and liquid nitrogen emission system.

DEAR Air Separation Solve YourWhy should the air separation tower be blown away and how should it be blown away correctly?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the Air separation unit instrument cluster and what is the relationship between transmitters, display tables, regulators, and membrane control valves?Air separation unit.1 g potassium dichromate or 2 g sodium nitrite can be added to each liter of water (not suitable for nonferrous metal degreasing); due to the toxicity or explosion of degreasing agent, attention must be paid to prevent poisoning and formation of explosive mixture. In alkaline cleaning, the pipeline with more oil stains is heated to 60-90 ℃ with 10% sodium hydroxide solution, then neutralized with 15% nitric acid and washed with clean water.Air separation unit.From the vaporization temperature (saturation temperature) of liquid oxygen, if the liquid oxygen surface is too high, the greater the static pressure difference between the upper and lower liquid oxygen surface, the higher the average pressure of liquid oxygen and the corresponding saturation temperature. In order to maintain the heat transfer temperature
2026.11.02
The air in nature is not absolutely dry, and a certain amount of gaseous water vapor is always mixed inside, which is a conventional part of air. Under normal pressure and normal temperature, water vapor is evenly dispersed in the air and will not condense into liquid water, so we cannot directly observe water. In the air separation operation, the air is first compressed by the air compressor. After the air is compressed, the volume is greatly reduced, and the density of water vapor in unit space increases sharply. At the same time, the saturated water content of air will change with the increase of pressure. Under high pressure, the upper limit of water vapor contained in air tends to be fixed. When the water vapor content exceeds the saturation value corresponding to the pressure, the air will reach the supersaturated state, which has the basis of water precipitation. The air compression process will generate a lot of heat, and the high temperature environment can temporarily improve
2026.10.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top