当前位置: Home / Faq / Large air separation FAQ /

Why should the air separation tower be blown away and how should it be blown away correctly?

Why should the air separation tower be blown away and how should it be blown away correctly?
Oct 12, 2022
Author: DEAR AST
Question Reply

Blowing off is the operation of removing solid impurities and free water by the impact of airflow, and at the same time, it can also expel part of the heat and cold energy stored in the equipment. After installation and overhaulAir separation equipmentIt is easy to remain solid impurities and water drops, so it should be blown away; when the device is stopped, the cooling capacity of expelling part should be blown away, and after the heating operation, it should also be blown away to expel part of heat and further clear away water.
There are roughly two blowing methods: continuous blowing and intermittent blowing. The so-called "continuous blowing-off" is the blowing-off method that always opens the blowing-off valve and lasts for a period of time. The so-called "Intermittent blow-off" means that the blow-off valve is closed and open at the same time. When it is closed, it is opened suddenly after holding high pressure, and it is repeated. This method has better effect on removing solid impurities and free water. Because the pressure difference increases when the pressure is suffocated, the airflow speed increases when the blow-off valve is opened, and the impact clamping effect strengthens.
If the drying gas is not used in the blowing-off process, the water in the cold equipment will reach saturation, and the water may be precipitated in the equipment, and even the water will freeze and freeze the pipeline and equipment. Moreover, after blowing off, the remaining wet gas in the equipment is easy to elude water drops when the temperature changes. To reach the purpose of equipment drying, it is best to use dry airflow to blow off. For cold equipment, when the temperature does not rise to above 0℃, do not blow off with wet air.
The blowing-off procedure is to clean the pipes outside the tower first to prevent the impurity from entering the tower; in the tower, first blow the air heat exchanger, and then blow off the tower, finally, blow the tower and liquid oxygen and liquid nitrogen emission system.

DEAR Air Separation Solve YourWhy should the air separation tower be blown away and how should it be blown away correctly?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top