When air enters into the cooler (or switching heat exchanger) through the last stage cooler of air compressor and nitrogen water precooler, the content of water vapor in the air has reached the saturated state. After that, with the decrease of temperature, the corresponding pressure of saturated water vapor is decreasing; the content of saturated water per cubic meter of air is gradually decreasing. For example, when the temperature drops from 30℃ to-60℃, the saturated moisture content in the air decreases from 30.3g/m3 to 0.011g/m3. The extra water is precipitated on the stuffing of the cooler or the fin of the Plate-fin Heat Exchanger. At-60℃, the saturated water vapor pressure has decreased to 1.067 Pa, which can be considered as no water, so 30℃ to-60℃ is called the water precipitation area. The "three-phase point" of water (the state of the coexistence of gas phase, liquid phase and solid phase) pressure is 0.613kPa, and the temperature is 0.01 ℃. When the partial pressure of t...