What are the criteria for judging whether the heating regeneration of molecular sieve in air separation equipment is complete?

What are the criteria for judging whether the heating regeneration of molecular sieve in air separation equipment is complete?
Sep 11, 2024
Author: DEAR AST

First of all, it is necessary to ensure that the gas pressure and flow rate required for heating the molecular sieve reach the level required by the process design. This is the basis of the heating regeneration process can be carried out smoothly.
Specific judgement criteria are as follows:
1, cold blowing peak temperature: usually, the cold blowing peak temperature needs to reach a certain standard (such as 80 ~ 120 ℃ or more, the specific value depends on the type of molecular sieve and operating conditions), in order to consider the regeneration is complete. This standard can be determined according to the actual operating experience and process design requirements.
2, regeneration gas flow and time: in the heating process, it is necessary to ensure that the regeneration gas flow and time meet the process requirements to ensure that the molecular sieve can be fully desorbed and regenerated.
3, molecular sieve performance in the work cycle: in addition to direct observation of the peak temperature of cold blowing, you can also indirectly determine whether its regeneration is complete by observing the performance of the molecular sieve in the work cycle. For example, observe whether the content of carbon dioxide and moisture in the working cycle is stable, and whether the temperature of air out of the molecular sieve is normal.
To determine whether the heating regeneration of molecular sieve is complete or not, it is necessary to consider a number of factors, including the heating conditions, regeneration process monitoring and specific judgement criteria. Through scientific methods and strict monitoring means, it can ensure that the regeneration effect of molecular sieve reaches the best state.

DEAR Air Separation Solve YourWhat are the criteria for judging whether the heating regeneration of molecular sieve in air separation equipment is complete?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top