Why does the air separation equipment require inflation before starting the water pump when starting the air cooling tower

Why does the air separation equipment require inflation before starting the water pump when starting the air cooling tower
Sep 04, 2023
Author: DEAR AST

When the air cooling tower is put into use, pilot gas is required before starting the water pump. This is a measure to prevent air from carrying water. Because the pressure of the air inside the tower before inflation is atmospheric pressure, when high-pressure air with a pressure of about 0.5MPa (gauge pressure) is introduced into the tower, due to the expansion of the volume, the pressure will suddenly decrease, and the airflow speed will sharply increase. Its impact and entrainment effect is strong. At this point, if the cooling water has already been sprayed, it is easy for the air to carry water when leaving the cooling tower. Therefore, it is required to inflate the tower first, and then start the water pump to supply water and spray after the pressure increases and the airflow stabilizes.

Furthermore, if the water pump is turned on first, it is easy to cause the water level in the air cooling tower to be too high, even exceeding the elevation of the air inlet pipe, which increases the resistance of the air compressor outlet pipeline and causes the turbine air compressor to surge. Some equipment require that the circulating water pump can only be started after the pressure inside the air cooling tower exceeds 0.35MPa (gauge pressure). When the pressure drops below this value during operation, the water pump will automatically stop.

DEAR Company has technological advantages and engineering technicians with practical equipment operation experience operate and manage customers' equipment to ensure long-term, stable, and safe operation.

DEAR Air Separation Solve YourWhy does the air separation equipment require inflation before starting the water pump when starting the air cooling towerYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the function of the distillation tower in air separation equipment?
2024.12.18
If the air temperature in the small air separation unit expander is lower than the liquefaction temperature corresponding to the local pressure, part of the gas will liquefy and droplets will appear in the expander. However, the rotating speed of the working wheel of the turbo expander is very high, and the droplet impact on the impeller will cause the impeller surface wear. The droplets may also be thrown to the gap ...
2024.12.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top