Air compressorThe gas generated by absorbing external air and compressing through the air cooler and drier, after separating the water in the air, the gas flowing into the nitrogen generator generally contains only nitrogen molecules and oxygen molecules.
When gas entersNitrogen making machineThe main engine has two absorption towers. The high-performance carbon molecular sieve with oxygen absorption is specially configured in the towers. Under pressure, according to the different "selective adsorbability" of nitrogen and oxygen in the airValveThe automatic switching of the two towers realizes the pressure absorption process of the two towers, and the pressure absorption process of the pressure diffusion, that is, the carbon molecular sieve adsorbs oxygen under pressure, while nitrogen passes through, is collected and transported.
When the adsorption is saturated, it will automatically switch to another absorption tower for pressure adsorption, and the main engine of the chilled nitrogen generator will release the air and discharge the adsorbed oxygen, so the technological process of continuously producing high concentration of nitrogen alternately. Close the nitrogen generator, nitrogen inlet valve and sampling valve, and also close the power switch of the nitrogen generator. Wait until the pressure relief of the system and the pipeline is completely finished, adjust the oxygen analyzer to sample and adjust the pressure of the pressure reducing valve to 1.0bar, adjust the sampling flow meter and adjust the air volume to about 1. Pay attention to the fact that the sample air volume should not be too large.
Begin to detect the purity of nitrogen. When the pressure of the compressed air source reaches above 0.7MPa, open the stop valve of the main entrance of the nitrogen generator, and then adjust the pressure reducing valve to reduce the pressure to about 0.4-0.5Mpa, meanwhile, pay attention to observe the pressure condition of the two adsorption tanks and whether the pneumatic valve can work normally. In addition to ensuring the structure of Nitrogen generator, keep the motor and pump shaft away as far as possible and use non-ferrous metal to prevent sparks, the operation should strictly abide by the operation specification before the cooling and starting of the liquid oxygen pump, the blow-off valve should be opened, and the chilled nitrogen generator should be sealed first and blown off by nitrogen at room temperature for 10 ~ 20 min, on the one hand, the oxygen is driven away, and at the same time, the seal is restored to the normal temperature clearance; turn the car, after confirming that there is no fault, start the pump, pay attention to whether the inlet pressure of the pump is stable, if the pressure fluctuates or the outlet pressure does not rise, the cavitation phenomenon may occur. The exhaust valve on the upper part of the pump body must be opened to continue cooling the oxygen pump. After the pressure tends to be stable, then control the pressure of sealing air 0.1005 ~ higher than that before sealing ~ 0.101MPa; first put in the sealed gas, adjust the nitrogen generator to the appropriate pressure, then open the inlet and outlet valves of the pump, and let the liquid oxygen enter the pump to cool down. At this time, the pressure of the sealed gas must be about 0.105MPa higher than the inlet pressure.

DEAR Air Separation Solve YourDeep cooling nitrogen generatorYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Before installing pipe , check the orientation of the container orifice, the orientation of the valve inlet and outlet is correct. The pipe fittings should be thoroughly cleaned ten net and strictly degreased, while opening the welding bevels etc. The welded pipe must be brushed with clean stainless steel wire for a very short time before welding. In order to reduce the cold box pipe welding mouth, can be prefabricated in a clean plant, and later for the final distribution. Piping principles, f...
2026.04.22
Why is the expander temperature of air separation equipment lower than liquefaction point very harmful?
2026.04.21
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top