How to judge the leakage in air separation equipment

How to judge the leakage in air separation equipment
Aug 31, 2023
Author: DEAR AST

When the leakage occurs in the air separation unit, the cooling capacity is insufficient and the main cooling liquid level drops continuously. If there is a large amount of gas leakage, the pressure rise in the cold box can be observed. If the cold box is not tight, a lot of cold air will come out of the gap. However, when the cryogenic liquid leaks, there is no obvious pressure rise and gas escape, and the base temperature often drops significantly.

 

Many units have accumulated some experience in the production practice, in order to have a preliminary judgment on the leakage position and leakage before shutdown maintenance, so as to shorten the shutdown time. (1) Test the purity of the gas escaping from the cold box. When nitrogen or liquid nitrogen leaks, the volume fraction of nitrogen in cold air can reach more than 80%; when oxygen or liquid oxygen leaks, the volume fraction of oxygen can be significantly increased. (2) Observe the "sweating" or "frosting" parts on the wall of the cold box. At this time, attention should be paid to the leakage of low-temperature liquid, and the "frosting" part is below the leakage point. (3) Observe the regularity of escaping gas. It is mainly used to judge the leakage of the switching channel of the switching heat exchanger. For the alternately used containers, the leakage position can be further determined by switching use. The above judgment methods are often combined.

 

In order to be familiar with the actual location and operation of the cold box, we need to accumulate experience.

DEAR Air Separation Solve YourHow to judge the leakage in air separation equipmentYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Another part of the nitrogen vaporized in the liquefier is heated up to a certain temperature in the high pressure heat exchanger and pumped out to the low pressure nitrogen press, the nitrogen separated by the gas-liquid separator is also heated up by the high pressure heat exchanger and then goes to the low pressure nitrogen press, compressed to a certain pressure by the low pressure nitrogen press and then back to the high pressure heat exchanger for heat exchange with liquid air separat...
2026.04.17
Special pressure-bearing equipment generally bears internal pressure, that will cause tensile stress inside the shell, which is called working stress. The working stress is directly proportional to the pressure and diameter, and inversely proportional to the vessel wall thickness. The axial stress is half of the circumferential stress. Therefore, for cylindrical vessels, the stress of longitudinal weld is twice that of girth weld. Because the geometric shape of the spherical shell is symmetrical to the spherical center, and the axial stress is equal to the circumferential stress in numerical value. Therefore, the wall thickness of the spherical vessel can be reduced by half as much as that of the cylindrical vessel under the same pressure and diameter.
2026.04.16
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top