How to judge the leakage in air separation equipment

How to judge the leakage in air separation equipment
Aug 31, 2023
Author: DEAR AST

When the leakage occurs in the air separation unit, the cooling capacity is insufficient and the main cooling liquid level drops continuously. If there is a large amount of gas leakage, the pressure rise in the cold box can be observed. If the cold box is not tight, a lot of cold air will come out of the gap. However, when the cryogenic liquid leaks, there is no obvious pressure rise and gas escape, and the base temperature often drops significantly.

 

Many units have accumulated some experience in the production practice, in order to have a preliminary judgment on the leakage position and leakage before shutdown maintenance, so as to shorten the shutdown time. (1) Test the purity of the gas escaping from the cold box. When nitrogen or liquid nitrogen leaks, the volume fraction of nitrogen in cold air can reach more than 80%; when oxygen or liquid oxygen leaks, the volume fraction of oxygen can be significantly increased. (2) Observe the "sweating" or "frosting" parts on the wall of the cold box. At this time, attention should be paid to the leakage of low-temperature liquid, and the "frosting" part is below the leakage point. (3) Observe the regularity of escaping gas. It is mainly used to judge the leakage of the switching channel of the switching heat exchanger. For the alternately used containers, the leakage position can be further determined by switching use. The above judgment methods are often combined.

 

In order to be familiar with the actual location and operation of the cold box, we need to accumulate experience.

DEAR Air Separation Solve YourHow to judge the leakage in air separation equipmentYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The non-power consuming option for liquid air separation plants can be used for full liquid air separation plants,where the produced liquid is sold off. This approach is currently available for most LNG receiving stations. For air separation units with a large cold capacity, the liquid air can be pressurised to 6baA in a vacuum storage tank, and then heat exchanged through a heat exchanger, instead of the air compressor, directly into the cold box for distillation. At the same time in the cold b...
2026.03.13
1. Before connecting the pipe orifice of each container, clean white cloth shall be used to tie the orifice to prevent grease and dirt from entering. 2. When welding in the cold box and in the condensing evaporator, it is strictly forbidden for flame or arc to touch the surface of vessels and pipes. 3. The containers, valves, pipes and corresponding supports in the cold box, the surface of the cold box and the foundation surface shall not be stained with grease after installation, otherwise, degreasing treatment shall be carried out.
2026.03.12
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top