当前位置: Home / Faq / Liquefied air separation FAQ /

How to judge the leakage in air separation equipment

How to judge the leakage in air separation equipment
Aug 31, 2023
Author: DEAR AST

When the leakage occurs in the air separation unit, the cooling capacity is insufficient and the main cooling liquid level drops continuously. If there is a large amount of gas leakage, the pressure rise in the cold box can be observed. If the cold box is not tight, a lot of cold air will come out of the gap. However, when the cryogenic liquid leaks, there is no obvious pressure rise and gas escape, and the base temperature often drops significantly.

 

Many units have accumulated some experience in the production practice, in order to have a preliminary judgment on the leakage position and leakage before shutdown maintenance, so as to shorten the shutdown time. (1) Test the purity of the gas escaping from the cold box. When nitrogen or liquid nitrogen leaks, the volume fraction of nitrogen in cold air can reach more than 80%; when oxygen or liquid oxygen leaks, the volume fraction of oxygen can be significantly increased. (2) Observe the "sweating" or "frosting" parts on the wall of the cold box. At this time, attention should be paid to the leakage of low-temperature liquid, and the "frosting" part is below the leakage point. (3) Observe the regularity of escaping gas. It is mainly used to judge the leakage of the switching channel of the switching heat exchanger. For the alternately used containers, the leakage position can be further determined by switching use. The above judgment methods are often combined.

 

In order to be familiar with the actual location and operation of the cold box, we need to accumulate experience.

DEAR Air Separation Solve YourHow to judge the leakage in air separation equipmentYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant cold energy utilises air separation equipment, generally large air separation equipment with 2 combined expanders. The price is around 4 million RMB. The expansion air in the air separation plant is no longer required, so for the internal compression process air separation, the inlet air volume of the circulating booster is reduced by about 40% (from 5.A-2A). The energy consumption of the booster is reduced and the investment is reduced. Liquid air separation equipmen...
2026.06.18
1.In the process of preparation and implementation of hoisting construction, the safety and quality assurance system must ensure the normal operation,to ensure that the hoisting project meets the requirements of safety and quality. Before hoisting, safety and quality inspection must be carried out, and it must comply with the code forLifting construction of chemical engineering construction (HG20201-2000) and other regulations and specifications. 2.The crane performance shall meet the requirements of hoisting process, and the alarm and hydraulic system must be reliable. 3.Strictly implement the provisions of the technical documents attached to the crane. 4.The hoisting schedule of auxiliary crane should match that of main crane. 5.The hook deflection angle shall not be greater than 3°. 6.It is forbidden to drag the unitdirectly on the ground with crane. 7.Before unithoisting, trial hoisting shall be carried out. The clear hoisting distance and the foundation change at
2026.06.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top