  1. The cold box foundation is composed of foundation body, water baffle, cold insulation layer and surface layer.

 

  1. The surface of fractionator foundation after completion shall meet the following requirements:
  2. a) There should be no cracks and other defects on the surface;
  3. b) The surface should be clean,and no inflammable materials such as wood board and linoleum are allowed to be carried;
  4. c) Surface flatness < 5 / 1000;
  5. d) The surface levelness is less than 5 / 1000, and the total length shouldnot be more than 15mm.

 

  1. After the foundation is qualified, mark the installation center line of the container according to the installation position of the vessel, and mark the direction and position of the pipe orifice.
DEAR Air Separation Solve YourConstruction requirements for fractionator foundationYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
How to store liquid products in air separation equipment?
2025.01.10
Air compressor intermediate cooler is generally shell-tube structure. Water is supplied inside the pipe, and gas is supplied between the pipes, which plays a cooling role through the heat exchange of fluid inside and outside the pipe. The reasons that affect the cooling effect of compressor intermediate cooler include: 1) insufficient cooling water. The heat of the air is not enough to be taken away by the cooling water, resulting in the increase of the next level of suction temperature, the decrease of gas density, and finally the reduction of exhaust volume. Therefore, the water supply pressure of cooling water should be closely monitored during operation to control the water supply. The process generally requires that the cooling water pressure should be greater than 0.15MPa (surface pressure); 2) the cooling water temperature is too high. High water temperature reduces the temperature difference between water and gas, and reduces the effect of heat and cooling. Even if the amoun...
2025.01.09
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top