当前位置: Home / Faq / Small air separation FAQ /

How to judge whether there is grease in the oxygen cylinder

How to judge whether there is grease in the oxygen cylinder
Sep 27, 2022
Author: DEAR AST

Grease is a combustible substance, which will cause spontaneous combustion when contacting with compressed oxygen with pressure greater than 3MPa. If grease is stuck on the oxygen cylinder valve, the cylinder valve will catch fire or even explode when oxygen flows through the cylinder valve at a high speed during the filling and use of the oxygen cylinder. Therefore, the oxygen cylinder is strictly forbidden to be stained with grease.

The grease on the bottle valve is caused by ignoring the safety and seriously violating the safety operation rules. Oil stained hands, gloves, work clothes and tools of the operator during filling and use; It is also possible that strict degreasing treatment is not carried out during inspection and replacement of bottle valves.

The grease in the bottle may be the gas containing grease once contained in the cylinder. During the periodic inspection of gas cylinders, in order to determine whether there is grease on the inner wall of the gas cylinders, the following methods can be used: pour the water used to rinse the gas cylinders into a cup, leave it for a while, put a piece of cigarette paper on the water surface, and take it out for drying after a while. If there is oil stain on the paper, it indicates that the bottle contains grease; Pour the water for rinsing the gas bottle into the cup, and use a small spoon to take a little pure camphor powder and sprinkle it on the surface of the cup. If the camphor powder rotates strongly on the water surface, it indicates that the bottle contains oil. This is because camphor powder is insoluble in water, but soluble in oil. In the process of dissolution, the heat of dissolution will be generated to vaporize the water locally, causing the rotation of camphor powder.

DEAR Air Separation is committed to providing high-quality complete sets of air separation equipment for customers at home and abroad, and also focuses on providing various types of spare parts for air separation. It has been recognized and trusted by customers!

DEAR Air Separation Solve YourHow to judge whether there is grease in the oxygen cylinderYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top