What are the management and requirements for valve installation and maintenance of air separation equipment

What are the management and requirements for valve installation and maintenance of air separation equipment
Jul 18, 2022
Author: DEAR AST

There are many valves in the air separation plant, and the following management and requirements are required for valve installation and maintenance.

Low temperature valves, valves on oxygen pipelines and valves in contact with oxygen medium must be free of oil, grease and any other impurities. When using, maintaining and repairing these valves, special attention should be paid to ensure that this point is not contaminated with oil, grease, wax and other flammable materials. If they have been in contact with oil, grease and other flammable materials, they should be degreased. The valve gasket, sealing packing and sealing ring must also be free of oil and grease, and must be made of non combustible materials suitable for oxygen valves. It is strictly forbidden to use oil-containing wax impregnation and combustible materials. The visible surface of the valve stem must be kept clean, and the surface of the valve stem should be regularly coated with a lubricant suitable for oxygen valves.

Check the leakage of the valve. Low temperature valves, oxygen pipelines and valves in contact with oxygen media must be cleaned and degreased strictly before installation. The solvents used for cleaning and degreasing must also be free of oil, grease and any other impurities. Decomposed solutions are not allowed. During the installation of valves, all solid substances such as slag, iron oxide scale, rust, welding slag, explosives (including grease, preservatives, etc.) must be removed from the installation of all valves.

In the process of equipment manufacturing and installation, DEAR air separation has detailed management and maintenance requirements for valves and special valves to ensure the high-quality operation of the equipment.

DEAR Air Separation Solve YourWhat are the management and requirements for valve installation and maintenance of air separation equipmentYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top