Analysis of the reasons why the liquid discharge valve cannot be closed

Analysis of the reasons why the liquid discharge valve cannot be closed
Jul 20, 2022
Author: DEAR AST

The content of liquid oxygen and acetylene in the liquid air in the air separation unit needs to be analyzed frequently, so the liquid oxygen and liquid air discharge valves need to be opened frequently. If there is water at the stuffing box of the valve, and the temperature drops when the liquid is discharged, it will cause the packing, valve rod and stuffing box to freeze together, and the valve rod will have difficulty in rotating or cannot rotate at all, resulting in difficulty in closing the valve. At the initial stage of liquid discharge, the valve rod should be rotated continuously to prevent this phenomenon. If the valve rod cannot rotate when frozen, steam should be used to heat the stuffing box and close the valve.

The intelligent cylinder manufacturing of DEAR air separation adopts the advanced intelligent CNC four roll rounding machine to roll the cylinder, realizing the automatic centering of feeding, and the automatic pre bending and rounding of input adjustment data; Make full use of the big data storage function of the rounding machine, through its own intelligent data screening, combined with the intelligent detection function, reasonably control the data exchange between the barrel radius of curvature and the work roll, so as to achieve accurate rounding data, realize the automatic rounding function, and improve the barrel production quality. Whether the ovality of the distillation column cylinder meets the standard is the basis to ensure that the equipment can meet the design technical indicators. The excessive ovality of the cylinder causes uneven assembly of structured packing and affects the distillation effect.

DEAR Air Separation Solve YourAnalysis of the reasons why the liquid discharge valve cannot be closedYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top