What measures should be taken in case of failure of booster turbine expander of air separation unit

What measures should be taken in case of failure of booster turbine expander of air separation unit
Jul 12, 2022
Author: DEAR AST

When the alarm device of the booster turbine expander of the air separation unit rings, it is the signal of the failure of the booster turbine expander. Consequences: the pressure of the processing air increases, affecting the operation of the air turbine compressor, and the liquid level of the main condensing evaporator decreases, resulting in a decrease in output.

Emergency measures shall be taken in case of failure of booster turbine expander of air separation unit:

Start the standby booster turbine expander; Adjust the discharge pressure of the booster compressor to stabilize the discharge pressure of the booster compressor, check the purity of the product gas, reduce the product volume, reduce the liquid discharge volume, or stop completely if necessary.

Further measures: eliminate the fault immediately; Adjust the air volume and output to normal values.

The common failure of booster turbine expander is the blockage caused by ice and dry ice, which requires heating. As for other faults, the causes should be found out and eliminated according to the regulations on the use and maintenance of booster turbine expander.

DEAR air separation equipment manufacturing technology has studied technical theories and principles through long-term experience, and the manufacturing technology is mature and standardized. Each sub equipment has formulated use and maintenance regulations, and strictly controlled each stage, with quality first, to ensure the safety and efficiency of the equipment.

DEAR Air Separation Solve YourWhat measures should be taken in case of failure of booster turbine expander of air separation unitYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Why do gas nitrogen and liquid nitrogen coexist at the top of the distillation tower of an air separation plant
2026.01.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top