Large air separation unit expander brake motor failure

Large air separation unit expander brake motor failure
Jun 17, 2022
Author: DEAR AST

The principle of the electric motor braking expander is to use the braking torque generated by the generator braking state of the motor to control the speed of the expander, if the braking motor fails, the expander speed will be out of control and it will overspeed. At this time, it is necessary to automatically open the protection control system, the method is that the speed measuring motor will send the overspeed signal, so that the three-way solenoid valve power off, the three-way solenoid valve directly controls the gas open pneumatic butterfly valve of the inlet of the expander, so that this butterfly valve quickly closed, the inlet air is cut off. At the same time, the valve stem rotates and touches the block and limit switch, so that the power supply to the expander motor is cut off to achieve safe parking.
DEAR company everything for the user, to provide customers with economic and reasonable project planning and programme design, project programme design plays a decisive role in the advanced and competitive ability of the product, is the core link of engineering construction, is an important part of the implementation of construction projects, is the key link in dealing with the relationship between technology and economics, is the key stage in controlling the cost of the project. Whether the technology used in the project is advanced and economically reasonable directly determines the reliability of the production of large air separation unit and operating costs. DEAR Air makes every effort to provide customers with perfect pre-sales services.

缅甸1500空分冷箱

DEAR Air Separation Solve YourLarge air separation unit expander brake motor failureYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquid air separation plant system uses the cold energy to produce liquid oxygen, liquid nitrogen and liquid argon in an air separation system, including an air compression pre-cooling system, an air purification system, an air separation system and a nitrogen circulation system for liquid air separation plant cold recovery. the nitrogen circulation system for liquid air separation plant cold recovery is placed in a separate cold box from the main cold box of the air separation system. the l...
2026.08.03
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top