Liquid air separation unit in the cold box piping considerations

Liquid air separation unit in the cold box piping considerations
Jun 16, 2022
Author: DEAR AST

In order to reduce the cold loss caused by improper piping arrangement in the cold box, the following points should be noted when piping in the cold box.
1, the pipelines can not touch each other, hot and cold pipes should be left a certain distance.
2, a variety of liquid pipeline or cold tube should be as close as possible to the internal cold container, gas pipeline arrangement in the liquid pipeline outside.
3, gas pipeline from the wall of the cold box should be a certain distance.
4、The liquid discharge pipeline should take measures to prevent the liquid from continuously vaporizing and increasing the cold loss.
DEAR Air uses its long-accumulated project management experience to help customers establish and improve project processes. Deere air separation engineering technology team has a long history of air separation engineering construction experts and professional and technical personnel, to provide users with various types of engineering business process planning services, and the establishment of a systematic and standardized service guarantee system. We adopt the principles of independence, science and fairness, and make comprehensive use of our knowledge and experience in engineering technology to ensure that each link is executed and handled in a fine manner, so that our customers are assured and satisfied.

秦皇岛安丰钢铁有限公司-KDON(Ar)-3000070000-900型空分设备

DEAR Air Separation Solve YourLiquid air separation unit in the cold box piping considerationsYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top