How to start the booster turbine expander for liquid air separation plant?

How to start the booster turbine expander for liquid air separation plant?
Aug 05, 2024
Author: DEAR AST

Steps to start the booster turbine expander for liquid air separation plants.

  1. Prepare the booster turbine expander for start-up in accordance with the requirements.
  2. The compressed air enters the lower tower in liquid air separation plant.
  3. High pressure air pressurised by the booster end of the booster turbine expander in liquid air separation plant, then cooled and throttled by the main heat exchanger into the lower tower; maintaining a lower tower pressure of around 0.35 MPa.
  4. The pressurised air (drawn from the middle of the main heat exchanger) going to the expander.
  5. Start the pressurised turbine expander and bring it gradually to full capacity operation.
  6. Pay attention to the speed of the expander and the air flow at the booster end during the opening of the expander nozzle, the air flow at the booster end can be adjusted by means of a valve.
  7. Keep the discharge pressure of the booster compressor stable.
  8. Disconnect and deactivate the backup instrument air source provided by the user and use the instrument air from the set itself instead.
  9. Adjustment of valves. All valve adjustments should be carried out step by step and slowly, when each operation has achieved the desired effect, before carrying out the next valve adjustment, do not operate too hard and too fast.
  10. Temperature control. Main heat exchanger group hot end temperature difference should be controlled within 3 ~ 3.5 ℃.
  11. The inlet temperature of the expander is controlled above -105°C to keep the booster expander running at high load.

DEAR Air Separation manufactures complete sets of small air separation units, large air separation units and liquid air separation plants and has had technical studies for many years to ensure safe and stable operation of the small air separation unit, large air separation unit and liquid air separation plant start-up.微信图片_20200217112035

DEAR Air Separation Solve YourHow to start the booster turbine expander for liquid air separation plant?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the Air separation unit instrument cluster and what is the relationship between transmitters, display tables, regulators, and membrane control valves?Air separation unit.1 g potassium dichromate or 2 g sodium nitrite can be added to each liter of water (not suitable for nonferrous metal degreasing); due to the toxicity or explosion of degreasing agent, attention must be paid to prevent poisoning and formation of explosive mixture. In alkaline cleaning, the pipeline with more oil stains is heated to 60-90 ℃ with 10% sodium hydroxide solution, then neutralized with 15% nitric acid and washed with clean water.Air separation unit.From the vaporization temperature (saturation temperature) of liquid oxygen, if the liquid oxygen surface is too high, the greater the static pressure difference between the upper and lower liquid oxygen surface, the higher the average pressure of liquid oxygen and the corresponding saturation temperature. In order to maintain the heat transfer temperature
2026.11.02
The air in nature is not absolutely dry, and a certain amount of gaseous water vapor is always mixed inside, which is a conventional part of air. Under normal pressure and normal temperature, water vapor is evenly dispersed in the air and will not condense into liquid water, so we cannot directly observe water. In the air separation operation, the air is first compressed by the air compressor. After the air is compressed, the volume is greatly reduced, and the density of water vapor in unit space increases sharply. At the same time, the saturated water content of air will change with the increase of pressure. Under high pressure, the upper limit of water vapor contained in air tends to be fixed. When the water vapor content exceeds the saturation value corresponding to the pressure, the air will reach the supersaturated state, which has the basis of water precipitation. The air compression process will generate a lot of heat, and the high temperature environment can temporarily improve
2026.10.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top