Why does the large air separation units liquid drain valve not close?

Why does the large air separation units liquid drain valve not close?
Apr 15, 2022
Author: DEAR AST

The acetylene content in liquid air and liquid oxygen needs to be analysed every day, so the liquid air and liquid oxygen discharge valves have to be operated every day.

The problem arises when it is easy to open the valve, but difficult to close it, sometimes even a little can not be closed. This is mainly due to the presence of moisture at the valve stuffing box. When the liquid is discharged, the temperature drops and freezing occurs. In order to prevent this, the valve should be turned continuously at the beginning of the discharge of the liquid so that the stem does not freeze. If freezing has occurred, steam can be used to heat the stuffing box before it is closed.

Dear Air Separation has a lot of practical experience in all aspects of technology, piping and valves in the long-term small air separation units manufacturing and design process, requiring high quality large air separation units and liquid air separation plants and providing a full range of technical services to customers.

上海宝冶集团有限公司-7500(2)

DEAR Air Separation Solve YourWhy does the large air separation units liquid drain valve not close?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top