当前位置: Home / Faq / Small air separation FAQ /

Special requirements for the construction of oxygen in small air separation units

Special requirements for the construction of oxygen in small air separation units
Apr 14, 2022
Author: DEAR AST

The structure of an oxygen press requires special requirements in order to ensure the safe operation of the oxygen press. Oxygen presses have a lower exhaust temperature than air compressors, so the number of stages is higher than for air compressors. Water lubrication or oil-free lubrication is required in the cylinder. The piston rod must be at least twice as long and have a well-sealed oil scraping device and an air leak recovery device. Any parts that come into contact with oxygen need to be made of stainless steel, copper alloy or aluminium alloy, which are resistant to oxidation and not easily sparked.

Dear Air Separation takes technology as the pioneer, the company's process calculation design, single equipment calculation design, pipeline stress calculation design, etc. all of those use international advanced software, advanced technology. The small air separation unit, large air separation units and liquid air separation plants are manufactured with the most advanced five-axis milling centre in the world.

微信图片_20200102093128

DEAR Air Separation Solve YourSpecial requirements for the construction of oxygen in small air separation unitsYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top