Liquid air separation plant circulating water systems design and operation management

Liquid air separation plant circulating water systems design and operation management
Jun 03, 2026
Author: DEAR AST

Water evaporation, wind-blown losses and other situations occurring in industrial circulating cooling water system operation, resulting in the continuous concentration of circulating water, then the salts contained therein exceed the standard, anions and cations increase, PH value changes significantly, resulting in the deterioration of water quality. The temperature of the circulating water rises and the PH value and nutrients increase, which is conducive to the reproduction of microorganisms.

Secondly, the cooling tower is an ideal place for algae to grow due to sufficient sunlight. And water cooling towers require circulating water treatment due to scaling and corrosion and microorganisms.

In many industrial sectors heat transfer media are required to transfer heat to the natural environment in time for the production process to run properly, as a large amount of waste heat is generated. Due to the excellent heat transfer properties of natural water and its low cost and abundance, water is often used as a heat transfer medium for industrial waste heat. In industrial production it is called cooling water. Industrial cooling water occupies a large amount of industrial water. Cooling water in addition to raising the temperature of the physical and chemical properties of cooling water is not very significant changes, if appropriate cooling measures are taken to form a recycling system, the recycling system is an important way to save industrial water.

 

The recycling system is a cooling water system that uses water as the cooling medium and recycles it. It consists mainly of liquid air separation plant cooling equipment, pumps and pipes. Cold water flows through the production equipment that needs to be cooled (often called liquid air separation plant heat exchange equipment, such as heat exchangers condensers, reactors), the temperature rises, if used immediately after the discharge of cold water only once called DC cooling water system. So that the warming cold water flowing through the liquid air separation plant cooling equipment then the water temperature back down, can be pumped back to the liquid air separation plant production equipment used again, the amount of cold water is greatly reduced, often can save more than 95%. Cooling water accounts for around 70% of industrial water consumption.

The cooling water system for liquid air separation plants designed by Deere Air can help customers to save a lot of industrial water.

311382bbb90b9c6052580c5af4981d3

DEAR Air Separation Solve YourLiquid air separation plant circulating water systems design and operation managementYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquid air separation plant system uses the cold energy to produce liquid oxygen, liquid nitrogen and liquid argon in an air separation system, including an air compression pre-cooling system, an air purification system, an air separation system and a nitrogen circulation system for liquid air separation plant cold recovery. the nitrogen circulation system for liquid air separation plant cold recovery is placed in a separate cold box from the main cold box of the air separation system. the l...
2026.08.03
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top