Cold energy usage process technology in liquid air separation plant 

Cold energy usage process technology in liquid air separation plant 
Dec 04, 2025
Author: DEAR AST

The raw air is compressed to about 0.52Mpa by the air compressor after filtering out dust and impurities, and then cooled to about 10℃ by the refrigerant glycol aqueous solution or Freon, and then enters the purification system to purify and remove water, carbon dioxide and other impurities in the air. Part of the raw material air enters the lower tower via the second raw material air pipeline, another part is liquefied into liquid air via the liquefier and enters the lower tower via the liquid air separation plant  pipeline, where the thermal mass is cross-condensed and evaporated, and the nitrogen, liquid nitrogen, dirty liquid nitrogen, poor liquid air and oxygen-rich liquid air are obtained in the lower tower in turn by the separation of the multi-layer tower plates.

Dear Air's high quality small air spearation unit, large air spearation unit and liquid air spearation plant have won the trust of customers at home and abroad.

山东传洋集团KDON(Ar)-1800036000-520型空分设备

DEAR Air Separation Solve YourCold energy usage process technology in liquid air separation plant You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Screw compressor is a positive displacement compressor from the mechanical type, which is composed of the driving rotor and driven rotor, the main body and a pair of synchronous gears. Therefore, the common faults of screw compressor are as follows: 1. The bearing is burnt out. Because of the foreign matter in the oil system, the oil pressure and the quality of the oil are reduced, resulting in the bearing burning out. The main treatment methods are: check the oil supply system; clean the oil filter and the cooling pipe of the oil cooler; check and adjust the oil pressure regulating valve; test the oil quality, and replace the oil when it is not good; check and deal with the oil leakage points. 2. The rotor is burnt out. When foreign matters enter into the compressed medium system, the temperature of the rotor rises, the temperature of the cooling oil of the rotor increases due to the high temperature of the inhaled medium, and the compression ratio increases, which may cause the
2026.03.20
Why only cryogenic air separation equipment can be selected for large industrial gas?
2026.03.19
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top