当前位置: Home / Faq / Liquefied air separation FAQ /

Liquid air separation plant traditional process

Liquid air separation plant traditional process
Nov 26, 2025
Author: DEAR AST

The nitrogen from the top of the upper tower is piped through the nitrogen gas pipeline, reheated through the main heat exchanger of the colder tower, and a portion of the nitrogen is pumped out, then combined with the first pipeline and a portion of the nitrogen vaporised in the liquefier in the third pipeline before going to the main vessel. The first raw material air pipeline is heated up and out of the cold box in liquid air separation plant, then goes to the high pressure heat exchanger of the cold box, the pipeline containing LNG is cooled to about 123°C and pumped out and sent to the low pressure nitrogen press, another part of the nitrogen vaporised in the liquefier is heated up to about 123°C through the fourth pipeline by the high pressure heat exchanger and pumped out and sent to the low pressure nitrogen press, the gas separated by the first gas-liquid separation is also heated up to about 103°C through the seventh pipeline by the high pressure heat exchanger and sent to the low pressure nitrogen press. 03 ℃, pumped out, sent to the low-pressure nitrogen press, after the low-pressure cycle nitrogen pressure booster returned to the high-pressure heat exchanger cooling, again cold that is to a 123 ℃ or so out of the medium-pressure cycle nitrogen press.

Dear Air manufactures and produces circulating nitrogen compressors of liquid air separation plant.山东钢铁集团(壶井)16000

DEAR Air Separation Solve YourLiquid air separation plant traditional processYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
When there is no pressure signal input, the valve is closed; when there is a pressure signal, the valve starts to open, and the larger the input signal, the larger the valve opening, this kind of film regulating valve is called air-opening film regulating valve in small air spearation unit. When there is no pressure signal input, the valve is fully open, and when there is a pressure signal input, the valve starts to close; the larger the input signal, the smaller the valve opening; when the inp...
2026.07.29
What is the cause of ultra low temperature in air separation plant and the principle of refrigeration equipment?
2026.07.28
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top