How to ensure the normal operation of liquid oxygen pump

How to ensure the normal operation of liquid oxygen pump
Jun 05, 2025
Author: DEAR AST
Question Reply

The liquid oxygen pump is a kind of low temperature liquid pump. It is used as the liquid oxygen circulating pump in the main condensing evaporator in the internal compressed air separation process to increase the pressure of liquid oxygen and output liquid oxygen.

 

Each set of internal compression process air separation plant is generally equipped with two liquid oxygen pumps, one for operation and one for standby. The operation of the liquid oxygen pump has a great impact on the operation quality of the air separation plant, and plays a key role. How to extend the operation period of the liquid oxygen pump is a subject that every air separation user pays much attention to and explores continuously.

 

After years of working practice, the technical personnel of DEAR air separation summarized the following experiences:

 

1.Before the start-up of the liquid oxygen pump, strict electrical instrument inspection shall be carried out to confirm that the turning gear is normal, and the liquid oxygen pump shall be pre-cooled to ensure that the temperature of impeller, shaft, seal ring and other components of the liquid oxygen pump is cooled to the working temperature before the start-up.

 

2.Strictly control the seal air pressure difference index during operation: the high orlow pressureof seal gas in the high-pressure liquid oxygen pump is very important for the stable operation of the liquid oxygen pump.

 

If the seal gas pressure is too high, the gas entering the pump body will easily lead to gas etching; if the seal gas pressure is too low, the liquid oxygen will easily leak out.

 

3.During the start-up process, it shouldbe paidclose attention to the electric current of the liquid oxygen pump, bearing temperature, seal gas pressure difference, temperature of seal gas and leakage gas and other parameters.

 

When the parameters fluctuate greatly, it should be taken relevant treatment measures in time.

 

4.After pre-cooling of the standby pump, the exhaust valve of the pump body and the blow afterpumpingvalve are slightly opened and in standby state at any time.

 

Through the application of the above methods and the implementation of the optimized operation, the operation cycle of the liquid oxygen pump will be greatly extended, providing a reliable guarantee for the safe operation of the air separation plant.

DEAR Air Separation Solve YourHow to ensure the normal operation of liquid oxygen pumpYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant cold energy utilises air separation equipment, generally large air separation equipment with 2 combined expanders. The price is around 4 million RMB. The expansion air in the air separation plant is no longer required, so for the internal compression process air separation, the inlet air volume of the circulating booster is reduced by about 40% (from 5.A-2A). The energy consumption of the booster is reduced and the investment is reduced. Liquid air separation equipmen...
2026.06.18
1.In the process of preparation and implementation of hoisting construction, the safety and quality assurance system must ensure the normal operation,to ensure that the hoisting project meets the requirements of safety and quality. Before hoisting, safety and quality inspection must be carried out, and it must comply with the code forLifting construction of chemical engineering construction (HG20201-2000) and other regulations and specifications. 2.The crane performance shall meet the requirements of hoisting process, and the alarm and hydraulic system must be reliable. 3.Strictly implement the provisions of the technical documents attached to the crane. 4.The hoisting schedule of auxiliary crane should match that of main crane. 5.The hook deflection angle shall not be greater than 3°. 6.It is forbidden to drag the unitdirectly on the ground with crane. 7.Before unithoisting, trial hoisting shall be carried out. The clear hoisting distance and the foundation change at
2026.06.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top