What are air-opening and air-closing membrane control valves in small air spearation unit?

What are air-opening and air-closing membrane control valves in small air spearation unit?
Jul 29, 2026
Author: DEAR AST

When there is no pressure signal input, the valve is closed; when there is a pressure signal, the valve starts to open, and the larger the input signal, the larger the valve opening, this kind of film regulating valve is called air-opening film regulating valve in small air spearation unit.

When there is no pressure signal input, the valve is fully open, and when there is a pressure signal input, the valve starts to close; the larger the input signal, the smaller the valve opening; when the input signal reaches the maximum, the valve is fully closed, this film valve is called gas-closed film adjustment valve.

In practice, the choice of gas open, gas closed mainly from the production of safety requirements to consider, the regulating valve is closed to the production of the smallest hazard, the choice of gas open type. If the valve is open when the least harmful, to choose the gas-closed type. Liquid-air-liquid nitrogen control valve, turbine expansion machine in front of the emergency shut-off valve are gas-open type. When the gas is cut off, the valve is in a closed state; turbomachine anti-surge valve in the gas cut off, the valve must be open, using gas-closed type. The venting valve on the oxygen storage tank and the nitrogen venting valve on the upper tower are gas-closed, so that in the event of a failure, power and gas outages can be bled to ensure safety.

In the design process, Dear Air has designed all aspects of technology, piping and valves to meet the international standards of the industry to ensure high quality requirements for small air spearation unit, large air spearation unit and liquid air spearation plant installation.

山东临沂钢铁集团(三德)-16000

DEAR Air Separation Solve YourWhat are air-opening and air-closing membrane control valves in small air spearation unit?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the enthalpy in the air separation plant?
2026.08.20
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top