What are the main measures taken for the design of oxygen pipelines in small air separation unit?

What are the main measures taken for the design of oxygen pipelines in small air separation unit?
Aug 06, 2026
Author: DEAR AST

The main measures taken for the design of oxygen piping in small air separation unit.

1、The piping material of the high-pressure oxygen gas pipeline is made of stainless steel to reduce the possibility of iron oxidation and combustion under intense working conditions.

2、Partial commercial flow rate piping using copper brocade alloy (Monel);

3, the use of different conditions of the pipeline proposed different degreasing and cleanliness requirements in the selection of Tong expansion joint for pipeline expansion compensation, the pipeline towards the design should be fully considered to reduce the radial vibration or displacement during the operation of the pipeline. of small air separation unit. The corresponding filter should be designed before the constant pressure regulating valve to prevent rust and debris from jamming the regulating valve. After the valve should be connected to a section of its length is not shorter than 5 times the diameter of the pipe, and not less than 1.5m of copper-based alloy or stainless steel piping to prevent fire.

4, oxygen pipeline should be set up as little as possible elbow and bifurcation, working pressure greater than 0.1MPa oxygen pipeline elbow, reducer should be made by stamping forming flange. Bifurcation head of the airflow direction should be 45 ° - 60 ° angle with the direction of the main airflow.

5, flange sealing ring should be used purple copper or polytetrafluoroethylene material О-type seal. Oxygen pipeline should be designed to eliminate static devices, grounding resistance, flange resistance are certain requirements.

6、The bifurcation head of oxygen pipeline should be made of rolled products, and it is strictly forbidden to open holes and plug in the field.

Dear air separation production and design of oxygen piping, to ensure the quality of design and installation and the subsequent long cycle of safe operation of small air spearation unit, large air spearation unit and liquid air spearation plant.

山东钢铁集团(壶井)

DEAR Air Separation Solve YourWhat are the main measures taken for the design of oxygen pipelines in small air separation unit?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top