当前位置: Home / Faq / Liquefied air separation FAQ /

Purging of liquid air separation plant 

Purging of liquid air separation plant 
Jan 27, 2022
Author: DEAR AST

 

  1. The purpose of the blowing is to clean out the residual slag, aluminium chips and other debris from the piping and vessels.
  2. the air source for blowing is provided by the turbine compressor, and the air cooling tower must be activated. 3.
  3. blowing principle, first outside the tower, after the tower, blowing brush to be one after another, in the blowing with the air pressure: low pressure system. Should be maintained at 40 a 50kpa high pressure system: should be maintained at 250 ~ 400kPa blowing pressure shall not exceed the working pressure of the container and pipeline, the flow rate should not be less than 20 / s
  4. In the system blowing, turbine expander booster liquid pump inlet and outlet pipe should be disconnected, its inlet pipe on the filter core, all the orifice flow meter orifice plate should also be removed.
  5. cold box outside the pipeline blowing, where the door connected to the cold box, should be to spoil into the door and tower.
  6. The blowing of the meter tube. Should be carried out in the late blowing brush. Blowing of each system should be repeated several times blowing time should not should be less than 4 hours.
  1. Checking whether the blowing bottom is restored or not. The white short-sheet paper and white cloth can be wetted and placed at the outlet of the mouthpiece. After 5 minutes, it should be clean without obvious mechanical impurities as qualified.

Dear Air carries out strict purging of liquid air separation plant and small air separation unit and large air separation unit

and  prior to installation.

莱芜项目-(2)

DEAR Air Separation Solve YourPurging of liquid air separation plant You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:   First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;   Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be man...
2024.11.21
How is the ratio of individual gases adjusted in an air separation plant?
2024.11.20
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top